5
Item
Model
YD-400AT3HGH
YD-400AT3HJE
Rated input voltage
V
3
—380 (50/60Hz)
3
—415 (50/60Hz)
Rated input capacity
kVA/kW
17.6/16.7
No-load voltage
V
71
Welding current
A
20~410
Force current
A
Max. 220
Start current
A
Max. 150
Rated output voltage
V
36
(
STICK
)
/26(SIMPLE TIG)
Rated duty cycle
%
60
Controlled mode
IGBT inverter
Cooling mode
Forced wind cooling
Insulated class
—
H
(
B for MTr
)
Degree of protection
—
IP23
Dimension of power source
(W×D×H)
mm
327 ×560× 602
Net weight of power source
kg
50
5.
Preliminary Arrangements for Operation
(1) Necessary Power Source and Connect Cable
Table 5.1
Model
Item
YD-400AT3HGH
YD-400AT3HJE
Rated Input Voltage
V
380
415
No. of Phases
3 phase
Facility
kVA
30 or more
Input protective
device
Fuse
A
40
No-fuse breaker
(Earth
leakage
breaker)
A
50
Input Cable
mm
2
6 or more
Output Cable
mm
2
35 or more
Cable
mm
2
Equal to or greater than the input side welding
power source
Notice:
□ Please unpack and take off the plastic sheet before using.
□ Make sure that turn off the switch box before connect the cables.
□ Attach a switch with fuse of specified capacity or no-fuse breaker (or leakage breaker) to the switch box
for each welding source.
□ Use the cable which is more than 10mm
2
if it is more than 10m.
□ If use the dynamo, then its facility is more twice than that of power source.
□ Reference [ relations between output current and output cable]