Settings
25
8.1.2 “CALL” and “RECORD”
Reminder
when delivery, Record & Call functions are set as disabled status.
●“Call” is a function to use stored welding conditions and “Record” is to store the well-tuned welding conditions.
Record/Call operation is applicable to the set values of current
・
voltage, spot welding time, arc characteristics,
penetration control, welding control, pulse ON/OFF, material, wire diameter, gas and F. Adj.
■
“ Call ” operation
Reminder
During the selection of Call, welding condition can NOT be changed (gas check and manual wire
feeding function work.)
No.
Operation
7-segment LED
1
Select Call in
○
12
( as shown in the picture on the right )
C H
O F F
2
Select channel (CH1-CH100) to be called in
○
7
(It alternately shows “CH” and current set value in
○
2
, channel and
voltage set value in
○
5
)
3
At present, ( welding condition is already being called) welding can
start.
4
After operation finishes, select
○
12
and return to “ welding ” mode
■
“ Record ” operation
Reminder
During Record operation, welding can’t start. (Gas check works.).
No.
Operation
7-segment LED
1
Select Record in
○
12
( as shown in the picture on the right )
2
Select the channel (CH1-CH100) to be used in
○
7
.
(It alternately shows “CH” and current set value in
○
2
,
channel and
voltage set value in
○
5
)
3
After operation finishes, select
○
12
and return to “ welding ” mode. Till
now data recording finishes.
Note:
During Call operation,
○
13
○
14
○
15
○
16
○
17
operation does not function.
8.2 The welding machine factory defaults reset
●
If 7-segment LED cannot display correctly after turning ON the power source, the damage of internal data may
happen. Please follow the steps here to restore machine to factory settings.
●
The operation sequence
1
.
Disconnect power source
;
2
.
After connecting the power source, at the moment when the software version is shown, hold
【
lock
】
and
【
welding control
】
button at the same time for 2 seconds. After welding machine finishes the display of the
software version, the display shown on the below picture happens. Thus the default setting is done successfully.
Please disconnect power source
;
- - -
- - -
2
5
Note:
Only when the display shown on the above picture on the welding machine, the power source can be switched off,
otherwise wrong operation would lead to the failure of the operation. And the second step should be done again.
3
.
After turning the power source again, welding machine restores to factory settings
;
4
.
Because the recorded data is reset to factory settings, please set according to your requirement.
Note:
During welding, there are certain errors of current and voltage between the value shown on LED and preset value.
It’s not a machine problem. During actual welding, the factors such as gas, wire diameter, welding technique and
extension length etc. can generate the above-mentioned errors.
Summary of Contents for YD-350GY4
Page 31: ...Operation 28 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 42: ...Parts list 39 12 Parts list 12 1 Parts list for YD 350GY4 Front view Rear view Top view ...
Page 43: ...Parts list 40 Right view Left view ...
Page 46: ...Parts list 43 12 3 Parts list for YD 500GY4 Front view Rear view Top view ...
Page 47: ...Parts list 44 Right view Left view ...
Page 50: ...Circuit diagram 47 13Circuit diagram 13 1 Circuit diagram for YD 350GY4HJE ...
Page 51: ...Circuit diagram 48 13 2 Circuit diagram for YD 500GY4HJE ...