21
15
°
Rotate
Main body
Camera fixing
screw
Camera mount
bracket
The mounting requirements are shown as follows.
* Make sure that the installed mount bracket can support more than 5 times of the weight of
the camera.
Mounting place
Ceiling/wall
Model
(Direct mounting)
Recommended
screw
M4 or equivalent
Number of
screws
4 pcs.
196 N {44.1 lbf}
Ceiling
WV-Q173
(Approx. 350
g
)
–
–
*
Minimum pull-
out strength of
a single screw
Step 7
Turn on the power of the camera.
Step 8
Adjust angular field of view and focus.
(
☞
pages 26 and 27)
Step 9
Place the upper cover onto the camera body
so that the projection of the bracket is
aligned with the notch of the upper cover.
Tighten the 3 screws. (Recommended tight-
ening torque: 0.59 N·m {0.44 lbf·ft}).
Attach
Step 6
Fix the camera and the camera mount brack-
et using the provided camera fixing screw
(M3 x 6) (tightening torque: 0.59 N·m
{0.44 lbf·ft}).
After fixing with the camera fixing screw,
check the following.
• The camera is placed on the level and
mounted firmly.
• The camera is not mounted shaky.