background image

The serial number of this product may be found on the
rear of the unit.
You should note the serial number of this unit in the
space provided and retain this book as a permanent
record of your purchase to aid identification in the event
of theft.

Model No. 

Serial No. 

THIS APPARATUS MUST BE EARTHED.

To ensure safe operation the three-pin plug supplied must be insert-
ed only into a standard three-pin power point which is effectively
earthed through the normal household wiring. Extension cords used
with the equipment must be three-core and be correctly wired to pro-
vide connection to earth. Wrongly wired extension cords are a major
cause of fatalities.
The fact that the equipment operates satisfactorily does not imply
that the power point is earthed and that the installation is completely
safe. For your safety, if in any doubt about the effective earthing of
the power point, consult a qualified electrician.

The lightning flash with arrowhead sym-
bol, within an equilateral triangle, is
interned to alert the user to the presence
of uninsulated "dangerous voltage" within
the product's enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an equilat-
eral triangle is intended to alert the user
to the presence of important operating
and maintenance (servicing) instructions
in the literature accompanying the appli-
ance.

WARNING:

TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK), NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

For Australia

ENGLISH VERSION

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CARE-
FULLY.
This appliance is supplied with a moulded three pin mains plug for your
safety and convenience.
A 13 amp fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the replacement
fuse has a rating of 13 amp and that it is approved by ASTA or BSI to
BS1362.
Check for the ASTA mark 

H

or the BSI mark 

G

on the body of the

fuse.
If the plug contains a removable fuse cover you must ensure that it is
refitted when the fuse is replaced.
If you lose the fuse cover the plug must not be used until a replacement
cover is obtained.
A replacement fuse cover can be purchased from your local Panasonic
Dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCK-
ET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE
REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY.
THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE
CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted please observe the wiring code as shown
below.
If in any doubt please consult a qualified electrician.

IMPORTANT

The wires in this mains lead are coloured in accordance with the follow-
ing code.

Blue:

Neutral

Brown:

Live

As the colours of the wire in the mains lead of this appliance may not

correspond with the coloured markings identifying the terminals in your
plug, proceed as follows.

The wire which is coloured BLUE must be connected to the terminal

in the plug which is marked with the letter or coloured black.

The wire which is coloured BROWN must be connected to the termi-

nal in the plug which is marked with the letter or coloured red.

Under no circumstances should either of these wires be connected to

the earth terminal of the three pin plug, marked with the letter or the
Earth Symbol 

I

.

How to replace the fuse
Open the fuse compartment with
a screwdriver and replace the fuse
and fuse cover.

For U.K.

Wij verklaren als enige aansprakelijke, dat het product waarop deze
verklaring betrekking heeft, voldoet aan de volgende normen of
andere normatiefve dokumenten, overeenkomstig de bepalingen
van Richtlijnen 73/23/EEC en 89/336/EEC.

Vi erklærer os eneansvarlige for, at dette produkt, som denne
deklaration omhandler, er i overensstemmelse med den følgende
standarder eller andre normative dokumenter i følge bestem-
melserne i direktivene 73/23/EEC og 89/336/EEC.

Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken
denna deklaration hänvisar är i överensstämmelse med standard-
dokument, eller andra normativa dokument som framstölls i Direktiv
73/23/EEC och 89/336/EEC.

Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä
ilmoitus koskee, noudattaa seuraavia standardeja tai muita ohjeel-
lisia asiakirjoja, jotka noudattavat direktiivien 73/23/EEC ia
89/336/EEC. säädöksiä.

Vi erklærer oss alene ansvarlige for at produktet som denne
erklæringen gjelder for, er i overensstemmelse med følgende
normer eller andre normgivende dokumenter som fælger bestem-
melsene i direktiven 73/23/EEC og 89/336/EEC.

We declare under our sole responsibility that the product to which
this declaration relates is in conformity with the standards or other
normative documents following the provisions of Directives
EEC/73/23 and EEC/89/336.

Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto
a cui si riferisce la presente dichiarazione risulta conforme ai
seguenti standard o altri documenti normativi conformi alle dispo-
sizioni delle direttive CEE/73/23 e CEE/89/336.

Summary of Contents for WVCM1470 - COLOR MONITOR

Page 1: ...Colour Monitor WV CM1470 Before attempting to connect or operate this product please read these instructions completely ...

Page 2: ...ULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET If a new plug is to be fitted please observe the wiring code as shown below If in any doubt please consult a qualified electrician IMPORTANT The wires in this mains lead are coloured in accordance with the follow ing code Blue Neutral Brown ...

Page 3: ...the specified temperature hunidity or power source ratings Use the monitor under conditions where temperature is between 10 C 50 C 14 F 122 F and humidity is below 90 The input power is 220 240 V AC 50 Hz Do not use the monitor in a car or other place where it may be exposed to severe vibration Severe vibration damage the monitor and cause the malfunction Do not stack two or more sets If more than...

Page 4: ... switch remains down for selecting S video signal and audio signal Press again The switch comes up l for selecting video signal and audio signal POWER ON OFF Colour Monitor WV CM 1470 PUSH INPUT AFC B A S VIDEO VIDEO LONG SHORT COLOUR BRIGHT CONTRAST PICTURE AUDIO MAX MIN t AFC Time Selection Switch AFC LONG SHORT This switch is used to select the AFC time Select LONG when the video signal is jitt...

Page 5: ...l for servicing 8 Screen Control SCREEN This control is preset at the factory Do not turn this control When adjustment is required ask a qualified service personnel for servicing 9 S VIDEO Input Connector for INPUT B INPUT B S VIDEO IN This connector receives S video signal from an exter nal source such as VTR for monitoring Connect a coaxial cable between this connector and S VIDEO OUT connector ...

Page 6: ...A VIDEO IN This BNC connector receives video signal from an external source such as VTR for monitoring Connect a coaxial cable between this connector and VIDEO OUT connector of external equipment 6 Video Output Connector for INPUT A INPUT A VIDEO OUT The video input signal received at the VIDEO IN con nector is looped through to this connector Connect a coaxial cable between this connector and VID...

Page 7: ... connect more than 10 monitors regardless of the diameter of the cable 1 Connect a coaxial cable between the S VIDEO OUT or VIDEO OUT connector of the camera or VTR and the S VIDEO IN or VIDEO IN connector of the first monitor 2 Connect a coaxial cable between the S VIDEO OUT or VIDEO OUT connector of the first monitor and the S VIDEO IN or VIDEO IN connector of the second moni tor and continue un...

Page 8: ...t the power cord to a grounded electrical out let Video Cable Follow these cautions to prevent from changing the imped ance of the cable and causing poor picture quality 1 Use 75Ω coaxial cable RG 59 U 3C 2V RG 6 U 5C 2V RG 11 U 7C 2V or RG 15 U 10C 2V Cable lengh between camera and monitor are shown below Type of coaxial cable Recommended maximum cable length m 250 500 600 800 825 1 650 1 980 2 6...

Page 9: ...ts WV Q104E to both sides of the monitor and fix them with screws M4 x 12 which are accessories of optional mounting brackets WV Q104E Cautions Leave one space free both above and below the monitor or install a cooling fan in the rack If the rack is subject to vibrations secure the rear of the unit to the rack using additional rack mounting brackets to be obtained locally RACK MOUNTING EIA Rack M4...

Page 10: ... 700 lines at centre Sweep Linearity Horizontal 5 or less Vertical 5 or less Sweep Geometry 2 or less Scanning Size Approx 6 Overscanning Scanning Frequency Horizontal 15 625 kHz Vertical 50 00 Hz Audio Input 8 dB Hi z 2 RCA pin jack Audio Output Loopthrough 2 RCA pin jack Speaker Output 0 7 W Ambient Operating Temperature 10 C 50 C 14 F 122 F Dimension 370 W x 354 H x 380 D mm 14 9 16 W x 13 15 1...

Page 11: ... 53 ...

Page 12: ...Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan N1197 0 YWV8QA4774AN Printed in Japan N 19 Gedruckt in Japan Imprimé au Japon Impreso en Japón ...

Reviews: