25
x
Connect an external amplifier-embedded speaker to the audio output cable (for use of the
audio transmission function).
SW559
Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.).
• Recommended cable length: Less than 10 m {32.8 ft}
c
Connect the alarm input/output cable.
<Ratings>
Terminal name
Ratings
ALARM OUT, AUX OUT
Open collector output (maximum applied voltage: 20 V DC)
Open
4 V DC - 5 V DC by internal pull-up
Close
Output voltage 1 V DC or less (50 mA or less)
ALARM IN, DAY/NIGHT IN Non-voltage make contact input (4 V DC - 5 V DC, internally pulled
up)
Off
Open or 4 V DC - 5 V DC
On
Make contact with GND (required drive current: 1 mA or more)
Note:
• Check if rating of an external device such as a sensor is applicable to the rating of this product
by referring to the provided operating instructions.
6SHFLƄFDWLRQRI3DODUPFDEOHDFFHVVRU\
*1'EODFN
$/$50,1$8;287JUD\7HUPLQDO
$/$50,1$/$50287UHG7HUPLQDO
$/$50,1'$<1,*+7,1JUHHQ7HUPLQDO
SW559
6SHFLƄFDWLRQRI3DODUPFDEOHDFFHVVRU\
*1'EODFN
$8;287JUD\7HUPLQDO
$/$50287UHG7HUPLQDO
$/$50,1JUHHQ7HUPLQDO
SW558
Summary of Contents for WV-SW559
Page 47: ...47 ...