background image

24

 3.  Move  the  cursor  to  ALARM  IN  2,  and  then  tilt  the 

joystick  left  and  right  to  select  the  operation  the 
camera  should  perform  when  an  external  signal  is 
received by ALARM IN 2. 

   

OFF 

:

 Ignore alarm input signals. 

   

2POSI 

:

 Move to preset position 2.  

   

SEQ 

:

 Start sequential movement. 

   

PATROL2 

:

 Start PATROL 2. 

   

AUTOTRACK2  :

 Move to preset position number 2, 

and then perform auto tracking. 

   

PATROL2 (S)  :

 Start  PATROL  2,  and  maintain  the 

stored  picture  quality  settings 
(page 17) even after completion. 

    The factory default setting is OFF.
 4.  Move  the  cursor  to  ALARM  IN  3,  and  then  tilt  the 

joystick  left  and  right  to  select  the  operation  the 
camera  should  perform  when  an  external  signal  is 
received by ALARM IN 3. 

   

OFF 

:

 Ignore alarm input signals. 

   

3POSI 

:

 Move to preset position 3.  

   

SORT 

:

 Start sort movement. 

   

PATROL3 

:

 Start PATROL 3. 

   

AUTOTRACK3  :

 Move to preset position number 3, 

and then perform auto tracking.

   

PATROL3 (S)  :

 Start  PATROL  3,  and  maintain  the 

stored  picture  quality  settings 
(page 17) even after completion. 

    The factory default setting is OFF.
 5.   Move the cursor to ALARM IN 4, and then tilt the 

joystick left and right to select the operation the 
camera should perform when an external signal is 
received by ALARM IN 4. 

   

OFF 

:

 Ignore alarm input signals. 

   

4POSI 

:

 Move to preset position 4.  

   

BW 

:

 Black  and  white  display  while 

signal is being input. 

   

PATROL4 

:

 Start PATROL 4. 

   

AUTOTRACK4  :

 Move to preset position number 4, 

and then perform auto tracking. 

   

PATROL4 (S)  :

 Start  PATROL  4,  and  maintain  the 

stored  picture  quality  settings 
(page 17) even after completion. 

    The factory default setting is OFF.

Notes:

•   Use  PATROL  1  (S)  to  4  (S)  if  you  want  to  switch 

picture  quality  (for  example  to  switch  picture 

quality from day to night) when an alarm input is 

received. ALARM IN4 can be used combined with 

BW. 

    To  use  the  camera  with  this  application,  set  the 

picture  quality  you  want  to  switch  before 

registering  the  patrol,  then  start  the  patrol 

registration  and  then  end  the  registration 

immediately.

•   If you want to change the picture quality settings 

according to alarm input for PATROL 1 (S) to 4 (S), 

the  settings  are  applied  to  the  camera  settings 

and  are  kept  even  after  the  camera  is  turned  on 

again.

•   PATROL1(S)-4(S) displays only the set number of 

patrol routines (page 17).

 6.   Move  the  cursor  to  CNT-CLS  1,  and  then  tilt  the 

joystick left and right to select the alarm output that 
should be performed over ALARM OUT 1 when an 
alarm is detected. 

   

OFF 

:

 No alarm output 

   

AUX1 

:

 Output  a  contact  close  signal  when 

AUX1  input  is  received  from  the  system 
controller. 

   

ALARM  :

 Output  an  alarm  signal  when  an  alarm  is 

detected by the motion detector (page 22) 
or  the  preset  alarm  (page  23).  After 
selecting  this  setting,  perform  step  7  to 
specify the alarm signal output time. 

    The factory default setting is OFF.
 7.  Move  the  cursor  to  TIME  OUT  and  then  tilt  the 

joystick  left  and  right  to  select  the  alarm  signal 
output time. 

    Tilting  the  joystick  cycles  through  the  output  time 

display in the sequence shown below. (unit: ms)

    The factory default setting is 100MS.

 
8.    Move  the  cursor  to  CNT-CLS  2,  and  then  tilt  the
      joystick left and right to select the alarm output that
      should be performed from ALARM OUT 2 when an
      alarm is detected. 
   

OFF 

:

 No alarm output 

   

AUX2 

:

 Output  a  contact  close  signal  when 

AUX2  input  is  received  from  the  system 
controller.

   

BW 

:

 Output  a  contact  close  signal  only  while 

the  camera  is  in  the  black  and  white 
mode. 

    The factory default setting is OFF.

 

 9.  Move  the  cursor  to  COAX  ALM  OUT,  and  then  tilt

      the joystick left or right to toggle it ON and OFF. 

    This setting turns alarm controls whether an alarm is 

output when the camera moves to one of the preset 

positions specified for ALARM IN 1 through 4 (1POSI, 

2POSI, 3POSI, 4POSI) in steps 2 through 5, above. 

   

ON 

:

 Output  an  alarm  signal  from  the  video 

output connector at the point the camera 

finishes  moving  to  a  preset  position 

(number 1 through 4) when there is alarm 

input to ALARM IN (1 through 4). 

   

OFF 

:

 No alarm signal output 

    The factory default setting is OFF.

Notes: 

•  The  camera  ignores  alarm  inputs  during  manual 

operation.

•  Turn  off  alarm  outputs  when  the  system  controller 

downloads or uploads the preset data. 

100 MS   

   200 MS   

   1000 MS   

↔ 

  2000 MS   

   4000 MS

Summary of Contents for WV-CW590G

Page 1: ...hese instructions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Operating Instructions Color CCTV Camera Model No WV CW590 G WV CW59...

Page 2: ...set Position Settings 6 n Language Setting 8 n Advanced Menu Settings 8 Camera settings 9 n Using the Camera Setup Menu 9 Pan tilt settings 14 n Using the Pan Tilt Setup Menu 14 Alarm settings 22 n Us...

Page 3: ...alled on the PC download the latest Adobe Reader from the Adobe web site and install it The model number is abbreviated in some descriptions in this manual The screens used in these operating instruct...

Page 4: ...ng is 1 7 Move the cursor to XON XOFF and then tilt the joystick left or right to select an XON XOFF setting NOT USE Disables XON XOFF data flow control USE Enables XON XOFF data flow control The fact...

Page 5: ...t or right to toggle camera ID display ON and OFF 2 Select ON or OFF and then press the CAM SET button The factory default setting is OFF 3 Use the joystick to move the cursor the character you want t...

Page 6: ...CAM SET button 2 Move the cursor to the number you want to select and then press the CAM SET button This registers the position number setting and displays the preset setting menu this page To select...

Page 7: ...then upload it to the camera with the damaged data l Preset ID Setting PRESET ID The preset ID is a series of alphanumeric characters that indicate the location of the camera 1 Move the cursor to PRE...

Page 8: ...ng Instructions show English display messages 3 Move the cursor to SET and then press the CAM SET button The item that was set flashes when the language is being changed and stops flashing when the la...

Page 9: ...er area to become washed out SUPER D6 digitally combines an image that is set up for a clear view of bright areas with an image that is set up for a clear view of dark areas creating a final image tha...

Page 10: ...d down and left and right to move the cursor to a cell you want to mask 2 Press the CAM SET button to mask the cell Moving the cursor to a cell that is already masked causes the blinking pattern of th...

Page 11: ...main highlighted on the display If this happens it could mean that the color temperature is outside the supported range or that illumination is too low 2 Select ATW1 ATW2 and AWC then press the CAM SE...

Page 12: ...UTO in step 1 move the cursor to LEVEL and then tilt the joystick left to select the threshold illuminace level for switching between the color mode and the black and white mode The illuminace shown b...

Page 13: ...rate This is the factory default setting The factory default setting is OFF Notes The stabilizer may not be effective for the following subjects Example Objects illuminated with low lighting Single co...

Page 14: ...position number in the range of 033 to 064 move the cursor to 33 64 in the lower left corner of the menu and then press the CAM SET button Preset numbers set subsequently are the same l Position Setti...

Page 15: ...he sequence shown below unit sec min The factory default setting is 10S l Scene File Setting SCENE FILE Up to 10 scene files each of which contains camera settings for a specific location scene can be...

Page 16: ...automatic return to a particular mode if a certain amount of time elapses without any operation being performed 1 Move the cursor to SELF RETURN and then tilt the joystick left or right to select a s...

Page 17: ...ctory default setting is 1 2 MIN Notes The auto mode is exited automatically whenever manual PAN TILT or ZOOM FOCUS is performed if AUTOPAN is operating and PAN TILT does SEQ SORT PATROL or AUTOTRACK...

Page 18: ...reaches 0S Notes Selecting LEARN to teach the camera a patrol routine causes the following parameters to be stored along with the camera movements 1 Parameters at the Beginning of the Routine PAN TIL...

Page 19: ...acy zone setting ON 1 Turns on the privacy zone function Grey ON 2 Turns on the privacy zone function Mosaic OFF Turns off the privacy zone function The factory default setting is OFF Use the followin...

Page 20: ...to track objects passing directly under the camera more smoothly The picture is flipped vertically and horizontally when the camera is at an angle of around 135 1 Move the cursor to DIGITAL FLIP and...

Page 21: ...ploads or downloads the preset data This protects against the download or upload failure due to start up of the cleaning process 5 Move the cursor to POSI and then press the CAM SET button This will d...

Page 22: ...detector to monitor for movement To mask screen areas use the same procedure as step 5 under SUPER D6 Super Dynamic 6 on page 9 After configuring mask settings press the MON ESC button to return to t...

Page 23: ...y accidents that occur or any losses incurred while this product is being used When in the preset position the preset position settings are in effect 2 Preset Alarm Setting PRESET ALM Turning on the p...

Page 24: ...the picture quality settings according to alarm input for PATROL 1 S to 4 S the settings are applied to the camera settings and are kept even after the camera is turned on again PATROL1 S 4 S display...

Page 25: ...The factory default setting is ALARM The names and types of displays for the alarm display are shown in the table below Notes Use a shortcut page 29 to switch between displaying or not displaying the...

Page 26: ...ress the F3 button The refresh function corrects the camera position when it starts to deviate from the preset positions 5 Returning Camera Settings to Their Defaults CAMERA RESET 1 To reset the camer...

Page 27: ...he factory default password is 123 4 Press the CAM SET button This returns to the setup menu and toggles PASSWORD LOCK on or off The password input screen will reappear if you press the CAM SET button...

Page 28: ...ain for verification Note that you cannot register the new password by pressing the MON ESC button 6 Input the new 3 digit password again by moving the cursor to each of the applicable numbers along t...

Page 29: ...FLIP OFF 8 0 CAM FUNCTION PROPO P T ON 8 1 CAM FUNCTION PROPO P T OFF 8 4 CAM FUNCTION SUPER D6 ON 8 5 CAM FUNCTION SUPER D6 OFF 8 6 CAM FUNCTION AF MODE AUTO 8 8 CAM FUNCTION Performs auto focus 8 9...

Page 30: ...AUTO switching time 10 seconds 1 9 2 CAM FUNCTION BW AUTO switching time 30 seconds 1 9 3 CAM FUNCTION BW AUTO switching time 60 seconds 1 9 4 CAM FUNCTION PATROL2 PLAY 1 9 5 CAM FUNCTION PATROL3 PLAY...

Page 31: ...orter s name and address to follow EU rules Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany Panasonic System Networks Co Ltd 2011 sC1011 1101 3TR0068...