background image

2

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

CAUTION

RISK OF ELECTRIC 

SHOCK DO NOT OPEN

The lightning flash with 

arrowhead symbol, within an 

equilateral triangle, is intended 

to alert the user to the presence 

of uninsulated "dangerous 

voltage" within the product's 

enclosure that may be of 

sufficient magnitude to 

constitute a risk of electric 

shock to persons.

The exclamation point within an 

equilateral triangle is intended 

to alert the user to the presence 

of important operating and 

maintenance (servicing) 

instructions in the literature 

accompanying the appliance.

WARNING:

•  This apparatus must be earthed.

•  Apparatus  shall  be  connected  to  a  mains 

socket  outlet  with  a  protective  earthing 

connection.

•  The mains plug or an appliance coupler shall 

remain readily operable.

•  To prevent fire or electric shock hazard, do not 

expose this apparatus to rain or moisture.

•  The  apparatus  should  not  be  exposed  to 

dripping or splashing and that no objects filled 

with liquids, such as vases, should be placed 

on the apparatus.

•  All  work  related  to  the  installation  of  this 

product  should  be  made  by  qualified  service 

personnel or system installers.

•  The  connections  should  comply  with  local 

electrical code.

CAUTION:

An  ALL-POLE  MAINS  SWITCH  with  a  contact 

separation  of  at  least  3  mm  in  each  pole  shall 

be  incorporated  in  the  electrical  installation  of 

the building.

FOR YOUR SAFETY PLEASE READ THE 

FOLLOWING TEXT CAREFULLY.

WARNING: This apparatus must be earthed.

IMPORTANT

The  wires  in  this  mains  lead  are  coloured  in 

accordance with the following code.

 

Green-and-yellow: 

Earth

 

Blue: 

Neutral

 

Brown: 

Live

  As the colours of the wire in the mains lead of 

this  appliance  may  not  correspond  with  the 

coloured  markings  identifying  the  terminals  in 

your plug, proceed as follows.

  The wire which is coloured 

green-and-yellow 

must  be  connected  to  the  terminal  in  the  plug 

which is marked with the letter 

E

 or by the earth 

symbol      or  coloured 

green

  or 

green-and-

yellow

.

  The  wire  which  is  coloured 

blue

  must  be 

connected  to  the  terminal  in  the  plug  which  is 

marked with the letter 

N

 or coloured 

black

.

  The  wire  which  is  coloured 

brown

  must  be 

connected  to  the  terminal  in  the  plug  which  is 

marked with the letter 

L

 or coloured 

red

.

Turn  the  power  off  at  the  mains  to  disconnect  the 

main power for all unit.

We declare under our sole responsibility that the product 

to which this declaration relates is in conformity with the 

standards  or  other  normative  documents  following  the 

provisions of Directives 2006/95/EC and 2004/108/EC.

Wij  verklaren  als  enige  aansprakelijke,  dat  het  product 

waarop deze verklaring betrekking heeft, voldoet aan de 

volgende  normen  of  andere  normatieve  documenten, 

overeenkomstig  de  bepalingen  van  Richtlijnen  2006/95/

EC en 2004/108/EC.

Vi  erklærer  os  eneansvarlige  for,  at  dette  produkt,  som 

denne  deklaration  omhandler,  er  i  overensstemmelse 

med standarder eller andre normative dokumenter i følge 

bestemmelserne  i  direktivene  2006/95/EC  og  2004/108/

EC.

Vi deklarerar härmed vårt fulla ansvar för att den produkt 

t i l l   v i l k e n   d e n n a   d e k l a r a t i o n   h ä n v i s a r   ä r   i 

överensstämmelse  med  de  standarder  eller  andra 

normativa dokument som framställs i direktiv nr 2006/95/

EC och 2004/108/EC.

Ilmoitamme yksinomaisella vastuullamme, että tuote, jota 

tämä  ilmoitus  koskee,  noudattaa  seuraavia  standardeja 

tai  muita  ohjeellisia  asiakirjoja,  jotka  noudattavat 

direktiivien 2006/95/EC ja 2004/108/EC säädöksiä.

Vi  erklærer  oss  alene  ansvarlige  for  at  produktet  som 

denne  erklæringen  gjelder  for,  er  i  overensstemmelse 

med  følgende  normer  eller  andre  normgivende 

dokumenter  som  følger  bestemmelsene  i  direktivene 

2006/95/EC og 2004/108/EC.

Summary of Contents for WV-CP290/G

Page 1: ...or operate this product please read these instructions carefully and save this manual for future use No model number suffix is shown in this manual Lens Option Operating Instructions Color CCTV Camera Model No WV CP290 G WV CP294E ...

Page 2: ...d with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured blac...

Page 3: ... your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the app...

Page 4: ...T LIMITED TO BELOW 1 ANY DAMAGE AND LOSS INCLUDING WITHOUT LIMITATION DIRECT OR INDIRECT SPECIAL CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT 2 PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER 3 UNAUTHORIZED DISASSEMBLE REPAIR OR MODIFICATION OF THE PRODUCT BY THE USER 4 INCONVENIENCE OR ANY LOSS ARISING WHEN IMAGES ARE NOT DISPLA...

Page 5: ...r of Warranty 4 Preface 6 Features 6 Precautions 6 Precautions for installation 8 Major operating controls and their functions 9 Installation and Connection 12 Optional dedicated lens 12 How to use a vari focal lens 16 Troubleshooting 17 Specifications 19 Standard Accessories 19 ...

Page 6: ... at temperature within 10 C 50 C 14 F 122 F and humidity below 90 When using this product without turning the power off Do not attempt to disassemble this product To prevent electric shock do not remove screws or covers There are no user serviceable parts inside Ask qualified service personnel for servicing Handle the product with care Do not abuse the product Avoid striking shaking etc The produc...

Page 7: ...urces A light source such as a spot light causes a blooming light bleeding or a smear vertical lines Turn the circuit breaker off which supplies this product with the power when abnormal conditions are encountered Smear Bright subject Blooming ...

Page 8: ... briny air such as seashores Locations where the temperature is not within 10 C to 50 C Locations subject to vibrations This product is not designed for on vehicle use Locations subject to condensation as the result of severe changes in temperature Avoid installing the camera in a place with a high level of noise Installation near an air conditioner an air cleaner a vending machine or the like cau...

Page 9: ...CP294 Rear view WV CP290 Rear view WV CP294 WV CP290 CH WV CP294CH 1 2 3 5 4 WV CP294CH 24V I N 1 L 12V I N NC 2 N GND INT ATW ON ON B S ON BLC D N LL AW C OF F OF F OF F VIDEO OUT 9 6 8 220 AC IN 240V INT ATW ON ON ON BLC D N LL AWC OFF OFF OFF 50Hz a VIDEO OUT BS 9 6 8 ...

Page 10: ...his terminal H Video output connector VIDEO OUT Composite video signals are transmitted If this unit is connected to the multiplex unit the multiplexed VD2 that is prioritized over INT LL is automatically selected I Dip switch Selects ON OFF for white balance mode backlight compensation Adaptive Black Stretch day night mode and INT LL for synchronization mode Day night mode selector D N ON Switche...

Page 11: ...tinuously measures the color temperature of the light source and automatically adjusts the white balance The adjustment of the color temperature ranges from approx 2 700 K to 6 000 K AWC Activates the automatic white balance control mode This adjustment is suitable for a location where a light source is stable The adjustment of the color temperature ranges from approx 2 000 K to 10 000 K Default s...

Page 12: ...tion of damage to the camera body use a lens with protrusion of 5 5 mm or less from the flange surface Optional dedicated lens Protrusion from flange 5 5 mm or less Protrusion from mount ø20 mm or less Caution Be sure to connect the grounding lead to the GND terminal WV CP290 Lens type Model No ALC lens for 1 3 inch CCD cameras 2x vari focal WV LZA61 2S WV LZA62 8S ...

Page 13: ...pull out strength196 N The other security measures to prevent dropping also must be considered when the total weight of camera and its lens is above 1 kg in addition to the fall protection measure functioned by coaxial cable in order to strengthen the fall protection countermeasure The fall protection measure can be functioned through the coaxial cable when the total weight is below 1 kg Orificio ...

Page 14: ...al to be strong enough because the tie plays the role of camera drop prevention measures in case When the camera mount bracket is mounted on a wall be sure to observe the mounting height described on the illustration below To video input Coaxial cables WV CP290 220 AC IN 240V INT ATW ON ON ON BLC D N LL AWC OFF OFF OFF 50Hz VIDEO OUT BS Camera mount bracket option The cable shall be tied to the ca...

Page 15: ...ped part of the wire is not exposed and is securely connected Ratings 24 V AC 12 V DC A 2 N GND B GND NC C 1 L C Tighten the screw of the power cord plug D Connect the power cord plug to the AC DC power terminal on the rear side of the camera Make sure that the power cord plug is inserted fully into the AC DC power supply terminal 24V I N 1 L 12V I N NC 2 N GND INT ATW ON ON B S ON BLC D N LL AW C...

Page 16: ... setting the lens focus to the FAR end When using a vari focal lens featuring the focus adjustment refer to the operating instructions of the lens in use How to use a vari focal lens The following are descriptions of how to use a 2x vari focal lens Method of adjustment may be different depending on the lens in use For further information refer to the operating instructions of the lens in use A Loo...

Page 17: ...eck whether the connection is appropriately established Is the monitor brightness appropriately adjusted or is the contrast appropriately adjusted Check whether the monitor settings are appropriate Is the lens cap detached Check whether the lens cap is removed Blurred image Is the lens of the camera soiled with dirt or dust Check whether the lens of the camera is clean Is the focus adjusted correc...

Page 18: ... The power cord power connector or power plug is damaged Use of the damaged cord connector or plug may cause electric shock or fire Disconnect the power plug immediately and request repair to your dealer Heated portion of power line consisting of power cord connector and power plug during use The power cord gets hot when bent or stretched ...

Page 19: ...equivalent to AGC Off weight On Video output 1 0 V P P PAL composite 75 Ω BNC Lens mount CS mount White balance ATW AWC Switch function White balance mode selector ATW AWC Backlight compensation selector ON OFF Adaptive Black Stretch selector ON OFF Day night mode selector ON OFF Synchronization mode selector INT LL Ambient temperature 10 C 50 C 14 F 122 F Ambient humidity Less than 90 Dimensions ...

Page 20: ... will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business use...

Page 21: ...sonic net Importer s name and address to follow EU rules Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany Panasonic System Networks Co Ltd 2010 sF0610 0 3TR006497AZB Printed in China ...

Reviews: