13
When installing the camera on a wall or ceiling, there are two methods as specified below.
• Use the one-gang junction box
• Installing the camera directly on a wall or ceiling
• Using the optional ceiling mount bracket WV-Q174E (for embedded installation on a ceiling)
Important:
• Procure 2 screws (M4) to secure the camera to a wall or ceiling according to the material of the
installation area. Do not use wood screws and nails. For mounting a camera on a concrete wall
or ceiling, use an anchor bolt (M4) for securing.
(Recommended tightening torque M4: 1.6 N·m)
• Required pull-out strength of a single screw/bolt is 196 N or more.
• If a ceiling board such as plaster board is too weak to support the total weight, the installation
area shall be sufficiently reinforced.
• The protection sheet attached to the dome section should be peeled off after installation.
The mounting conditions of the camera are described as follows:
Preparations
Mark
Mark
[|]
Note:
• The clear dome cover and the inner dome
are joined into a single unit.
Therefore, never try to remove them.
Installation
place
Applicable mount
bracket
Recommended
screw
Number
of screw
Minimum pull-out
strength (per 1 pc.)
Ceiling / wall
One-gang junction box
(locally procured)
M4
2 pcs.
196 N
Ceiling / wall
(Direct mounting)
M4
2 pcs.
196 N
Ceiling
WV-Q174E (approx. 310
g
) -
-
*1
*1 Make sure that the installed mount bracket can support more than 5 times of the weight of the camera.
Remove the dome cover
1
Peel off the protection sheet from the dome
cover. Don't remove completely as this
protects the dome during installation.
2
Loosen the dome cover fixing screw.
3
Adjust the mark on this unit to [|] on the
dome cover, and turn the dome cover
counterclockwise to remove it.