background image

Specifications

Power source and power 
consumption:

AC 24 V, 50 Hz, 2.7 W
DC 12 V, 220 mA

Image sensor:

1/3 inch interline transfer CCD

Effective pixels:

752 (H) x 582 (V)

Scanning area:

4.9 (H) x 3.7 (V) mm

Scanning system:

2 : 1 interlace

Scanning lines:

625 lines

Scanning frequency:

Horizontal: 15.625 kHz
Vertical: 50.00 Hz

Synchronization:

Internal, multiplexed vertical drive (VD2)

Resolution:

Horizontal: 540 TV lines (at center)
Vertical: 400 TV lines (at center)

Video output:

1.0 V[p-p] PAL composite 75 

White balance:

ATW/AWC

Signal-to-noise ratio:

50 dB (equivalent to AGC Off, weight On)

Minimum illumination:

0.6 lx (C/L), 0.05 lx (B/W), F1.3 (WIDE)

Switch function:

White balance selector (ATW/AWC), Backlight compensation selector
(ON/OFF), Adaptive Black Stretch selector (ON/OFF), Day/night mode
selector (ON/OFF)

Lens:

3.6x variable focal lens

Focal length:

2.8 mm - 10.0 mm

F number:

F1.3 (WIDE) - F3.1 (TELE)

Focus range:

- 1.2 m

Angle of view:

Horizontal:100°50' (WIDE) - 27°39' (TELE)
Vertical:73°51' (WIDE) - 20°45' (TELE)

Adjusting angle:

Panning range: +180 ° to –140 °
Tilting range: ±75 °
Azimuth range: ±100°

Ambient temperature:

–10 °C - +50 °C 

Ambient humidity:

Less than 90 %

Dimensions:

ø129.5 mm x 93 mm (H)

Weight:

430 

g

Weights and dimensions indicated are approximate. 

Standard Accessories

CD-ROM* ...............................................1 pc.
Operating Instructions (this document) .1 pc.
* The CD-ROM contains the operating instructions(PDF).

Ceiling Mount Bracket.....................WV-Q168
Dome Cover (smoke type) ..............WV-CF5S

Optional Accessories

Cable type

Extensible length

RG-59/U (3C-2V)

0

Approx. 250 m 

RG-6/U (5C-2V)

00

Approx. 500 m 

RG-11/U (7C-2V)

0

Approx. 600 m 

RG-15/U (10C-2V)

Approx. 800 m 

Connections

Video output connection

Important:

When connecting the coaxial cable to the
video output connector, make sure that the
connector of the coaxial cable is locked
firmly.

Connect the video output connector to the
monitor, or other system devices, with the pro-
cured coaxial cable. 
The maximum extensible cable length is shown
in the table. 

Power connection 

Connect the three-conductor cable of thecam-
era to the power supply. The wire colours and
functions are shown in the table.  

Wire colour

12 V DC

24 V AC

Brown

Positive

Live

Blue

Negative

Neutral

Green/yellow

Grounding

Grounding

Caution:

Be sure to connect the GND (grounding)
lead of the camera and grounding terminal
of the power supply when using a 24 V AC
power source. 

Cable Length and Wire Gauge

24 V AC 

The recommended cable length and thickness
are shown in the table for reference. The volt-
age supplied to the power terminals of the
camera should be within 19.5 V AC and 28 V
AC.

Copper wire
size (AWG)

Length of
Cable
(Approx.)

#24

(0.22 mm

2

)

20

#22

(0.33 mm

2

)

30

#20

(0.52 mm

2

)

45

#18

(0.83 mm

2

)

75

Recommended wire gauge for 24 V AC line.

(m)

12 V DC 

Use the formula below to calculate the power
cable and power supply. The voltage supplied
to the power terminals of the camera should be
within 10.8 V DC and 16 V DC. 

10.8 V DC 

V

A

- 2 (R x I x L) 

16 V DC

L:

Cable length (m)

R:

Resistance of copper wire (

/m)

V

A

:

DC output voltage of power supply
unit

I:

DC current consumption (A)
See specifications.

Video output connector

Power cable

Copper wire
size (AWG)

Resistance

/m

#24

(0.22 mm

2

)

0.078

#22

(0.33 mm

2

)

0.050

#20

(0.52 mm

2

)

0.03

#18

(0.83 mm

2

)

0.018

Resistance of copper wire [at 20 °C]

2. Zoom and focus adjustment

At the same time as adjusting the pan and
tilt(Step 2), adjust the zoom and focus.

q

Loosen the zoom lock lever and move the
lever between TELE and WIDE to obtain
the appropriate angle of view. Tighten the
zoom lock lever. 

w

Loosen the focus lock lever and move the
lever between FAR and NEAR to obtain
the optimum focus. Tighten the focus lock
lever. 

Note:

To change the angle of view by mov-
ing the zoom lock lever, also move the
focus lock lever to adjust the focus. 

w

Rotate the tilting table to adjust the tilting
position of the camera (Range: ±75 °).

• This lens can also be rotated in the

reverse direction, but the image azimuth is
reversed. In such a case, turn the panning
table to the 180 ° side to correct the
azimuth image. 

• When used at an angle that is close to hor-

izontal, it must be noted that the shadow
of the dome cover may be projected. 

• Fasten the tilting lock screws of both sides

after adjusting.

Variable tilt angle

Focus lock lever

Zoom lock lever

Indication

Panning 
table lock 
screw

Panning table

Indication
CCD up side

Indication

Rotating angle

Rotating angle

Azimuth adjuster

Image Adjustment 

1. Pan, tilt and azimuth adjustment 
Important:

• Do not touch the iris motor. Failure to

observe this may cause trouble. 

• Do not hold the camera by the lens unit

when adjusting panning, tilting, or
azimuth. 

At the same time as the pan and tilt adjust-
ments, make the zoom and focus adjustments
in Step 2. 

q

Rotate the panning table to adjust the
panning position of the camera. (Range:
320°) 

• The adjusting range is from +180 ° (clock-

wise) to –140 ° (counterclockwise).

• Tighten the panning table lock screw after

adjusting. 

e

Rotate the top cover clockwise to adjust the
marker to "III". 

2. Fix the top cover and the camera main

unit by means of an accessory fixing
screw (M3). 

Assembling the Camera

1. Mount the top cover.

q

Adjust the marker of this unit to "I" on the
top cover to install the top cover. 

w

Adjust the inner dome. 
Rotate the top cover clockwise to adjust the
marker to "II". 
Turn the dome cover block to the right and
left, watching the monitor. Make adjust-
ments so that no eclipse is caused. 

Important:

For inner dome adjustments, adjust the
marker to the position of "II". 
If the dome cover block is moved with
unreasonable force, it may break. 

Marker

Top cover

Dome cover block
(clear dome & inner 
dome section)

Top cover fixing screw (M3)

Important:

Tighten the panning table lock screw and
tilting lock screw.(Recommended tighten-
ing torque:0.59 N·m{6 k

g

f·cm})

e

Rotate the azimuth adjuster to adjust the
azimuth angle of the image (Range:
±100°).

Summary of Contents for WV-CF364E

Page 1: ...s been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped S3125A Limitation of Liability THIS PUBLICATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR ANY PAR TICULAR PURPOSE OR NON INFRINGEMEN...

Page 2: ...m perature tracking mode The camera continuously measures the color tem perature of the light source and auto matically adjusts the white balance The adjustment of the color tempera ture ranges from approx 2 700 K to 6 000 K AWC Activates the automatic white bal ance control mode This adjustment is suitable for a location where a light source is stable The adjustment of the color temperature range...

Page 3: ...r terminals of the camera should be within 10 8 V DC and 16 V DC 10 8 V DC VA 2 R x I x L 16 V DC L Cable length m R Resistance of copper wire Ω m VA DC output voltage of power supply unit I DC current consumption A See specifications Video output connector Power cable Copper wire size AWG Resistance Ω m 24 0 22 mm2 0 078 22 0 33 mm2 0 050 20 0 52 mm2 0 03 18 0 83 mm2 0 018 Resistance of copper wi...

Page 4: ...ur local retailer upon the purchase of an equivalent new product Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be appl...

Reviews: