Specifications
Power source and power
consumption:
AC 24 V, 50 Hz, 2.7 W
DC 12 V, 220 mA
Image sensor:
1/3 inch interline transfer CCD
Effective pixels:
752 (H) x 582 (V)
Scanning area:
4.9 (H) x 3.7 (V) mm
Scanning system:
2 : 1 interlace
Scanning lines:
625 lines
Scanning frequency:
Horizontal: 15.625 kHz
Vertical: 50.00 Hz
Synchronization:
Internal, multiplexed vertical drive (VD2)
Resolution:
Horizontal: 540 TV lines (at center)
Vertical: 400 TV lines (at center)
Video output:
1.0 V[p-p] PAL composite 75
Ω
White balance:
ATW/AWC
Signal-to-noise ratio:
50 dB (equivalent to AGC Off, weight On)
Minimum illumination:
0.6 lx (C/L), 0.05 lx (B/W), F1.3 (WIDE)
Switch function:
White balance selector (ATW/AWC), Backlight compensation selector
(ON/OFF), Adaptive Black Stretch selector (ON/OFF), Day/night mode
selector (ON/OFF)
Lens:
3.6x variable focal lens
Focal length:
2.8 mm - 10.0 mm
F number:
F1.3 (WIDE) - F3.1 (TELE)
Focus range:
∞
- 1.2 m
Angle of view:
Horizontal:100°50' (WIDE) - 27°39' (TELE)
Vertical:73°51' (WIDE) - 20°45' (TELE)
Adjusting angle:
Panning range: +180 ° to –140 °
Tilting range: ±75 °
Azimuth range: ±100°
Ambient temperature:
–10 °C - +50 °C
Ambient humidity:
Less than 90 %
Dimensions:
ø129.5 mm x 93 mm (H)
Weight:
430
g
※
Weights and dimensions indicated are approximate.
Standard Accessories
CD-ROM* ...............................................1 pc.
Operating Instructions (this document) .1 pc.
* The CD-ROM contains the operating instructions(PDF).
Ceiling Mount Bracket.....................WV-Q168
Dome Cover (smoke type) ..............WV-CF5S
Optional Accessories
Cable type
Extensible length
RG-59/U (3C-2V)
0
Approx. 250 m
RG-6/U (5C-2V)
00
Approx. 500 m
RG-11/U (7C-2V)
0
Approx. 600 m
RG-15/U (10C-2V)
Approx. 800 m
■
Connections
●
Video output connection
Important:
When connecting the coaxial cable to the
video output connector, make sure that the
connector of the coaxial cable is locked
firmly.
Connect the video output connector to the
monitor, or other system devices, with the pro-
cured coaxial cable.
The maximum extensible cable length is shown
in the table.
●
Power connection
Connect the three-conductor cable of thecam-
era to the power supply. The wire colours and
functions are shown in the table.
Wire colour
12 V DC
24 V AC
Brown
Positive
Live
Blue
Negative
Neutral
Green/yellow
Grounding
Grounding
Caution:
Be sure to connect the GND (grounding)
lead of the camera and grounding terminal
of the power supply when using a 24 V AC
power source.
●
Cable Length and Wire Gauge
24 V AC
The recommended cable length and thickness
are shown in the table for reference. The volt-
age supplied to the power terminals of the
camera should be within 19.5 V AC and 28 V
AC.
Copper wire
size (AWG)
Length of
Cable
(Approx.)
#24
(0.22 mm
2
)
20
#22
(0.33 mm
2
)
30
#20
(0.52 mm
2
)
45
#18
(0.83 mm
2
)
75
Recommended wire gauge for 24 V AC line.
(m)
12 V DC
Use the formula below to calculate the power
cable and power supply. The voltage supplied
to the power terminals of the camera should be
within 10.8 V DC and 16 V DC.
10.8 V DC
≤
V
A
- 2 (R x I x L)
≤
16 V DC
L:
Cable length (m)
R:
Resistance of copper wire (
Ω
/m)
V
A
:
DC output voltage of power supply
unit
I:
DC current consumption (A)
See specifications.
Video output connector
Power cable
Copper wire
size (AWG)
Resistance
Ω
/m
#24
(0.22 mm
2
)
0.078
#22
(0.33 mm
2
)
0.050
#20
(0.52 mm
2
)
0.03
#18
(0.83 mm
2
)
0.018
Resistance of copper wire [at 20 °C]
2. Zoom and focus adjustment
At the same time as adjusting the pan and
tilt(Step 2), adjust the zoom and focus.
q
Loosen the zoom lock lever and move the
lever between TELE and WIDE to obtain
the appropriate angle of view. Tighten the
zoom lock lever.
w
Loosen the focus lock lever and move the
lever between FAR and NEAR to obtain
the optimum focus. Tighten the focus lock
lever.
Note:
To change the angle of view by mov-
ing the zoom lock lever, also move the
focus lock lever to adjust the focus.
w
Rotate the tilting table to adjust the tilting
position of the camera (Range: ±75 °).
• This lens can also be rotated in the
reverse direction, but the image azimuth is
reversed. In such a case, turn the panning
table to the 180 ° side to correct the
azimuth image.
• When used at an angle that is close to hor-
izontal, it must be noted that the shadow
of the dome cover may be projected.
• Fasten the tilting lock screws of both sides
after adjusting.
Variable tilt angle
Focus lock lever
Zoom lock lever
Indication
Panning
table lock
screw
Panning table
Indication
CCD up side
Indication
Rotating angle
Rotating angle
Azimuth adjuster
■
Image Adjustment
1. Pan, tilt and azimuth adjustment
Important:
• Do not touch the iris motor. Failure to
observe this may cause trouble.
• Do not hold the camera by the lens unit
when adjusting panning, tilting, or
azimuth.
At the same time as the pan and tilt adjust-
ments, make the zoom and focus adjustments
in Step 2.
q
Rotate the panning table to adjust the
panning position of the camera. (Range:
320°)
• The adjusting range is from +180 ° (clock-
wise) to –140 ° (counterclockwise).
• Tighten the panning table lock screw after
adjusting.
e
Rotate the top cover clockwise to adjust the
marker to "III".
2. Fix the top cover and the camera main
unit by means of an accessory fixing
screw (M3).
■
Assembling the Camera
1. Mount the top cover.
q
Adjust the marker of this unit to "I" on the
top cover to install the top cover.
w
Adjust the inner dome.
Rotate the top cover clockwise to adjust the
marker to "II".
Turn the dome cover block to the right and
left, watching the monitor. Make adjust-
ments so that no eclipse is caused.
Important:
For inner dome adjustments, adjust the
marker to the position of "II".
If the dome cover block is moved with
unreasonable force, it may break.
Marker
Top cover
Dome cover block
(clear dome & inner
dome section)
Top cover fixing screw (M3)
Important:
Tighten the panning table lock screw and
tilting lock screw.(Recommended tighten-
ing torque:0.59 N·m{6 k
g
f·cm})
e
Rotate the azimuth adjuster to adjust the
azimuth angle of the image (Range:
±100°).