2
●
To Control a Recorder and Cameras via the Network
The following describes the connection between a recorder and this unit to control the recorder and camera via the network.
1. Set the unit address of the recorder to 5 or higher. (Refer to the recorder's operating instructions.)
2. Set the [Camera control] setting to "PSD" for all cameras in the recorder SETUP MENU.
3. Connect the unit's CAM OUT 1 to 16 connectors to the recorder's VIDEO IN 1 to 16 connectors with coaxial cable.
4. Connect the unit's EXT IN connector to the recorder's MULTISCREEN OUT connector with a coaxial cable.
5. Connect the unit's DATA HDR and DATA 4 connectors to the recorder DATA port with a branched modular cable.
6. Select the recorder's new unit address, which is set in Step 1, in 600 RECORDERS of SETUP MENU or the Recorder win-
dow of WJ-SX150A Administrator Console. (Refer to this unit's operating instructions.)
Notes:
• Select the PS.Data protocol for the DATA 4 setting. (Refer to this unit's operating instructions.)
• If the recorder unit address, set in Step 1, and the recorder setting, set in Step 6, are different, the recorder will not be
operable.
• You cannot use a PS.Data system controller with these connections.
• From system controllers connected to the unit, you cannot control monitors connected to the MONITOR OUT 1 connector
of the recorder.
AUX IN
AUDIO OUT
IN
OUT
16
15
14
13
12
11
10
9
8
7
6
5
4
3
5
3
1
6
4
2
1
2
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
MONITOR1
MONITOR2
RS485(CAMERA)
MODE
1 2
DATA
10/100BASE-T
COPY1
ALARM IN/CONTOROL
AUDIO IN
SIGNAL GND
POWER
ON
OFF
AC IN
AUDIO IN/ALARM OUT
VIDEO
SERIAL
SIGNAL GND
POWER
AC IN
CAMERA
1
1
2
2
3
3
2
DATA 3 DATA 2
SERIAL
ALARM
TERM
OFF
ON
4
2
1
4
3
CAMERA
SW IN
RS485(CAMERA)
LINE
SELECT
MONITOR OUT
EXT IN
(PLAY IN)
EXT OUT
(REC OUT)
OUT
IN
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
RS485(CAMERA)
DATA 4
DATA HDR
PS•DATA
DATA 1
System controller
(Terminal Mode)
EXT IN
MONITOR OUT
Recorder*
* Set the recorder's unit address to 5 or larger.
** LAN: Local Area Network
DATA 4
(PS
·
Data)
DATA
DATA HDR
MONITOR 1
HUB/Router
LAN**
Monitor
WV-CA48/10K