Appearance

q

Operate Indicator (OPERATE)

Is on when the power of the WJ-MPU855 CPU is
turned on.

Note:

The power switch of the CPU is located

underneath the front panel.
Remove the front panel by removing two
screws on the panel.

w

Reset Button (RESET)

The RESET button is recessed inside the front panel
hole to the right of the OPERATE indicator.

Press this button when the CPU rejects control from
outboard equipment.

e

Fan Alarm Indicator (FAN ALARM)

Indicates the cooling fan status.
This LED lights when a temperature rise in the CPU
is detected.  Turn the power off and refer servicing
to qualified service personnel.

r

HDD (Hard Disk Drive) Indicator (HDD)

Indicates the hard disk drive status.

t

Active Indicator (ACTIVE)

Indicates the system status of the CPU.

y

Ethernet Ports (ETHERNET)

Exchange control data via Ethernet.

• SYSTEM CONTROLLER

This port is provided for controlling the 850 System
with the WV-CU850 system controllers. Up to 64
controllers can be connected to this port through a
hub.

Note:

The total number of system controllers con-

nected via RS-485 and Ethernet is limited to 64.

OPERATE

RESET

FAN  ALARM

HDD

ACTIVE

Central Processing Unit  WJ–MPU

855

q

w

t r

e

Front View

• CAMERA/CROSS POINT/OSD

This port is used to exchange control data between
the cages through a hub.

• OTHER

Reserved for future use.

u

Controller Ports [SYSTEM CONTROLLER (RS-
485)]

These ports are provided for controlling the 850
System with the WV-CU350 system controllers. Up
to 12 controllers can be connected

i

Peripheral Interface Ports [PERIPHERAL
INTERFACE (RS-232C)]

These ports are reserved for future use or factory
tests.

o

Redundant CPU selector (REDUNDANT CPU)

Selects either a redundant system or a standalone
system.
The factory default setting is NO.

!0

Mode Selector (SATELLITE MODE)

Always keep in STANDALONE position.

!1

Parallel Port (PARALLEL)

This port is used to connect to the WJ-MPS855 CPU
Switch Unit for a redundant system.

!2

Cooling Fan Unit

Prevents the temperature of the CPU from rising.
Do not block the ventilation opening on the cover.

!3

Fuse Holder

!4

AC Inlet Socket (AC IN)

Plug the power cord (supplied as a standard
accessory) into this socket and connect it to an AC
outlet.

PARALLEL

REDUNDANT

CPU

RSATELLITE

MODE

ETHERNET

1

OTHER

CAMERA

CROSS POINT

OSD

GYGTEM

CONTROLLER

DATA  12

DATA  11

DATA  10

DATA  9

DATA  8

DATA  7

DATA  6

DATA  5

DATA  4

DATA  3

DATA  2

DATA  1

PERIFERAL  INTERFACE   (RS–232C)

(RS–485)

SYSYTEM

CONTROLLER

2

3

SATELLITE

STANDALONE

YES

NO

AC IN

Central Processing Unit

125V  3.0A

SIGNAL
GND

y

u

o !0 !1

!2

!3

i

!4

Rear View

Summary of Contents for WJ-MPU855

Page 1: ...o comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 2: ... q w t r e Front View CAMERA CROSS POINT OSD This port is used to exchange control data between the cages through a hub OTHER Reserved for future use u Controller Ports SYSTEM CONTROLLER RS 485 These ports are provided for controlling the 850 System with the WV CU350 system controllers Up to 12 controllers can be connected i Peripheral Interface Ports PERIPHERAL INTERFACE RS 232C These ports are r...

Page 3: ...ack mounting screws Cautions The cooling fans inside the CPU are subject to wear and need to be replaced periodically Do not block the ventilation opening or slots on the cover to prevent the appliance from overheating Always keep the temperature in the rack within 50 C 122 F Secure the rear of the appliance to the rack by using the additional mounting brackets procured locally if the rack is subj...

Page 4: ...50 Katella Ave Cypress CA 90630 714 373 7840 Specifications Power Supply 120 V AC 60 Hz Power Consumption 90 W Controllable Cameras 1 024 cameras 8 card cages Cross Point Controllable Cages 1 024 x 256 32 card cages Controllable Monitors 256 2 card cages System Controller Ports Ethernet 10Base T 8 conductor modular jack x1 Maximum 64 controllers RS 485 6 conductor modular jack x12 Maximum 12 contr...

Reviews: