23
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Bi-Bloc system
Product features
Easy maintenance
and assembly
• compact design
• easy control of the water pressure through a gauge in the front casing
• easy to open - hydromodule and outdoor unit
• flexible assembly due to long piping
• piping up to 30 metres with a height difference up to 20 metres
(for models up to 9 kW)
• piping up to 40 metres with a height difference of up to 30 metres
(for models with 12 to 16 kW)
• the piping connection to the outdoor units can occur in four directions
(front, rear, side, bottom)
Supply water
temperature (°C)
Outside
temperature (°C)
Cooling mode
1
Maximum
20
43
Minimum
5
16
Heating mode
Maximum
55 / 65
2
35
Minimum
25
-20
3
1
valid for models with cooling mode
2
valid for Aquarea HT
3
If the outside temperatures drop below the specified value, the heating capacity decreases