118
Aquarea air / water heat pump – design handbook 07 / 2014
Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea LT
Outside temperature
Supply water temperature
Models
30
35
40
45
50
55
12 kW (three phase)
WH-SDC12F9E8¹
WH-SDF12C9E8
WH-SDC12C9E8
(Phase-out models)
-15
9 .3
8 .7
8 .5
8 .1
7 .5
7 .0
-7
10 .4
10 .1
9 .6
9 .2
8 .7
8 .0
2
11 .8
11 .4
11 .0
10 .6
9 .8
9 .1
7
12 .0
12 .0
12 .0
12 .0
12 .0
12 .0
25
12 .0
12 .0
11 .8
11 .7
11 .5
11 .4
30
35
40
45
50
55
14 kW (three phase)
WH-SDC14F9E8¹
WH-SDF14C9E8
WH-SDC14C9E8
(Phase-out models)
-15
9 .9
9 .4
9 .0
8 .6
7 .9
7 .3
-7
11 .1
10 .9
10 .2
9 .8
9 .1
8 .6
2
12 .9
12 .1
11 .9
11 .4
10 .4
9 .5
7
14 .0
14 .0
14 .0
14 .0
13 .6
13 .3
25
14 .0
14 .0
14 .0
14 .0
14 .0
14 .0
30
35
40
45
50
55
16 kW (three phase)
WH-SDC16F9E8¹
WH-SDF16C9E8
WH-SDC16C9E8
(Phase-out models)
-15
10 .6
10 .5
10 .0
9 .7
8 .8
7 .9
-7
11 .9
12 .0
10 .8
10 .3
9 .6
9 .3
2
13 .5
13 .3
12 .4
11 .9
10 .8
9 .8
7
16 .0
15 .8
16 .0
15 .6
15 .2
14 .5
25
16 .0
16 .0
16 .0
16 .0
16 .0
15 .9
Heating capacity [kW] of individual models of the
Bi-Bloc system
for different supply water and outside temperatures [°C].
¹
Preliminary specifications