231
20.2 Heating Capacity Table
20.2.1 WH-MXC09J3E5
Rating Frequency
Water Out
25ºC
25ºC
35ºC
Outdoor Air
Capacity
Input Power
Capacity(W)
Input Power
Current(A)
Capacity(W)
Input Power
Current(A)
-25
-20
9000
3440
15.7
9000
3950
18.1
-15
9000
2980
13.6
9000
3410
15.6
-10
0.0
0.0
-7
8500
2800
10500
2720
12.4
9000
2920
13.4
2
7800
2300
10800
2140
9.9
9000
2360
10.9
7
9000
1380
6.5
9000
1770
8.3
25
9000
770
3.8
9000
1000
5.0
Water Out
45ºC
55ºC
60ºC
Outdoor Air Capacity(W) Input Power Current(A) Capacity(W) Input Power Current(A) Capacity(W) Input Power Current(A)
-25
-20
9000
4650
21.3
7900
5580
25.5
-
-
-
-15
9000
4040
18.5
9000
4830
22.1
8700
5370
24.6
-10
0.0
0.0
0.0
-7
9000
3540
16.2
9000
4240
19.4
9000
4620
21.1
2
9000
2910
13.5
9000
3550
16.4
9000
4050
18.7
7
9000
2370
11.1
9000
2920
13.7
9000
3290
15.4
25
10000
1670
7.9
10000
2280
10.7
11000
2860
13.4
Summary of Contents for WH-MXC09J3E5