7
2.2 WH-MHF12G6E5
Item
Unit
Refrigerant System
Performance Test Condition
EN14511
Heating Capacity
Condition
(Ambient/Water)
A7W35 A2W35
kW 12.00
12.00
BTU/h 41000
41000
kcal/h 10320
10320
COP
W/W 4.46
3.26
kcal/hW 3.84
2.80
Air Flow
m
3
/min (ft
3
/min) 80.0
(2830)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S
(1600)
Refrigerant (R407C)
g (oz)
1.92k (67.8)
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4-poles)
Rated Output
kW
3.40
Fan
Type
Propeller
Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
—
Output Power
W
60
Fan Speed
rpm
510 (Top Fan) 550 (Bottom Fan)
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 51 × 18
Size (W × H × L)
mm
903.7 × 1295.4 × 38.1
Item
Unit
Mono Bloc Unit
Dimension
Height
mm (inch)
1410 (55-1/2)
Width
mm (inch)
1283 (50-1/2)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
151 (333)
Noise Level
dB-A 50
Power Level dB
67
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power
kW
2.69
3.68
Maximum Input Power For Mono Bloc Unit
kW
6.20
Power Supply 1: Phase (ø) / Max. Current (A) / Max. Input Power (W)
Single / 29.0 / 6.20k
Power Supply 2: Phase (ø) / Max. Current (A) / Max. Input Power (W)
Single / 26.0 / 6.00k
Power Supply 3: Phase (ø) / Max. Current (A) / Max. Input Power (W)
- / - / -
Starting Current
A
12.8
Running Current
A
12.8
17.2
Maximum Current For Mono Bloc Unit
A
29.0
Power Factor
%
93
93