74
12.18 External OFF/ON Control
Communication circuit between indoor unit and external controller is as per below.
External
Controller
Panasonic
PCB
CN-THERMO
5V
12V
1
2
mico
Maximum length of communication cable is 20 meter.
Control
content:
External Control Switch
Control Panel OFF/ON
Control Panel Power LED
System Status
ON ON ON ON
ON OFF OFF OFF
OFF ON ON OFF
OFF OFF OFF OFF
REMOTE
ON
ON
ON
ON
OFF
OFF
UNIT
OFF
OFF
OFF
ON
CONTROLLER
During EXTERNAL SW OFF,
display “EXT SW OFF”
LED
REMOTE
CONTROLLER
SIGNAL
EXTERNAL
CONTROLLER
SWITCH
OPERATION
ACTUAL
HEATER
BOOSTER
QUIET
SETTING
STATUS
SERVICE
AUTO
HEAT
COOL
TANK
HEATER
FORCE
°C
°C
ON
OFF
MON TUE WED THU
FRI
SAT SUN
hr
hr
kwh
* During External Switch OFF condition, it is allow to change the setting and also timer operation.
Summary of Contents for WH-MDC05F3E5
Page 27: ...27 10 1 2 Solar Printed Circuit Board Optional ...
Page 44: ...44 57 C 57 C 57 C 57 C ...
Page 45: ...45 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 57 C 57 C 50 C 50 C ...
Page 137: ...137 21 26 23 11 9 7 20 5 1 6 24 68 25 70 73 13 12 10 4 4 27 2 3 4a 4a 8 62 75 49 48 ...