background image

© Panasonic Corporation 2020

PNQX9067ZA

C0320MM0

1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8501, Japan
http://www.panasonic.com

Summary of Contents for VL-SWD275

Page 1: ...lease read the nameplate on the bottom or rear of the product R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories specified by the manufacturer R The installation shall be carried out in accordance with all applicable ...

Page 2: ... damage existing wiring and ductwork R Do not make any wiring connections when the power supply is turned on R Do not use the supplied power supply unit for outdoor installations it is for indoor use only R Do not install the main monitor extension monitor in the following places Places where the main monitor extension monitor may be splashed with water or chemicals Places where there is a high co...

Page 3: ...18 mm thick walls R To prevent serious injuries due to the product unexpectedly falling the product with a wall mount feature must be installed at a height of 2 m or lower Supplied accessories for installation For the doorphone 1 Mounting base 1 Screw 2 3 8 mm 20 mm Screw 4 4 mm 12 mm For the main monitor extension monitor Screw 2 4 mm 16 mm Mounting bracket 1 Power supply unit and related items 2...

Page 4: ...ect to water R Depending on the installation location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor extension monitor R Install the main monitor away from electronic appliances such as TVs radios personal computers air conditioners boiler control panels with intercom home securi...

Page 5: ...ontact 2 PBX A A NP NP NP NP NP NP NP NP NP NP NP Terminal box 4 conductor wiring You can also connect an optional lobby station See page 7 1 1 POWER SUPPLY UNIT 24 V DC 3 Power supply 1 When you use an additional doorphone the maximum number of the electric locks that can be connected to the doorphone depends on the type of doorphone Consult your dealer for further information For VL V554 users T...

Page 6: ...nt national installation and or equipment regulations shall be considered A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used 2 When an extension monitor is used make sure that the total wiring length from the doorphone to the main monitor and then to the extension monitor is within about 100 m 3 When using an electric l...

Page 7: ...onitor with terminal D1 D2 on the lobby station Connect terminal S1 S2 on the main monitor with terminal S1 S2 on the lobby station After connecting to the main monitor change the Lobby connection setting to Device connected using the main monitor Operating Instructions of the Video Intercom System Note R Connection for VL V901 and VL V700 series Video Intercom System for Apartment Complexes Conne...

Page 8: ...doorphone step 3 Installing the doorphone so that the image range can be changed Side view when the camera is installed lower than the standard position and facing upwards at 15 Top view when the camera is facing left or right at 15 1 R Example Installation height is 1100 mm Units mm R Example Camera angle faces left 15 A B C D E F G H I J K L M A Image range B Approx 54 C Centre of doorphone D Ap...

Page 9: ...all the mounting base on a vertical flat wall B D 1 A C A Screws accessory 2 C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a hole for wiring as much as possible When using flush mount box option Model No VL MB524 Install the flush mount box A in the wall A C D E B B Knockout hole 1 C Approx 90 mm D Approx 138 mm E Approx 37 mm 1 Only open the knockout holes as required for t...

Page 10: ...the wires to the terminal connectors non polar then tighten the screws A 1 A Recommended torque 0 5 N m 5 1 kgf cm Maximum torque 0 7 N m 7 1 kgf cm 5 Attach the doorphone to the mounting base A A Screws accessory 4 When using flush mount box option Model No VL MB524 Attach the doorphone to the flush mount box A A Screws locally procured 4 R 4 mm 25 mm stainless steel the same type of screw as the...

Page 11: ...ory the AC cable accessory and a DC cable locally procured A A 7 mm Front view B C D E F G 1 1 Make sure that there are no core conductor wires A exposed outside the product Power supply unit with cable cover removed Top view Bottom view J H I J DC cable binder hole 1 Strip the DC cable as follows DC cable A 2 Remove the screw B and then remove the cable cover C 3 Connect the AC cable D accessory ...

Page 12: ... location that your eyes are the same height as the centre of the display R For the following reasons leave at least 20 cm A of space above below and to the left and right sides of the main monitor extension monitor To prevent malfunction and sound cutting out To ensure to make sure the reset button B can be used the reset button is on the side of the main monitor extension monitor 1 1 2 1 1 R Aft...

Page 13: ...ing on the button A pull out the wire B C A D C Core conductor wire at tip 9 mm D Wiring from doorphone or other device For power supply unit attached models VL SWD275AZ VL MWD275AZ etc Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 How to connect the DC cable A Remove screw A and then remove the terminal cover B While pressing on the button ...

Page 14: ... cable Damage may occur Note R Do not remove the terminal cover Excluding power supply unit attached models VL SWD275AZ VL MWD275AZ etc 3 Mount the main monitor extension monitor to the mounting bracket For power supply unit non attached models VL SWD275BX VL MWD275BX etc 3 1 Line up the tab on the bottom of the bracket with the groove on the main monitor extension monitor 3 2 Line up the tab on t...

Page 15: ...itor 3 2 Line up the tab on the top of the bracket with the groove on the main monitor extension monitor and push the main monitor extension monitor down until it is secure Notes about electrical wiring When wiring from bottom Make sure not to pinch the wires as shown below on the mounting bracket when installing R Do not forcibly attach to the mounting bracket 15 ...

Page 16: ... Panasonic Corporation 2020 PNQX9067ZA C0320MM0 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com ...

Reviews: