background image

Installation Guide

Model Name

Video Intercom System

Door station

Model No.

VL-SVN511 Series

VL-V555

R

This guide is for use with the above 2 models.

R

The VL-SVN511 models composition consists of VL-MVN511 and VL-V555.

VL-MVN511

VL-V555

Main monitor station

Door station

R

For VL-V555 users: Please read the areas related to the VL-V555 and also please refer to
the installation guide of the main monitor that the doorphone is connected to.

R

Door station is described as "doorphone" and Main monitor station is described as "main
monitor" in this guide.

R

In this guide, the suffix of each model number (e.g., the "BX" in "VL-SVN511BX") is omitted
unless necessary.

Note to the installer

R

Before attempting to connect or operate this product, please read the label on the rear of
the doorphone and the main monitor.

R

Please read this guide carefully, and install the product safely and correctly by following
the instructions. Carefully read the information found in the section titled "For your
safety" in particular.

R

Only use attachments/accessories specified by the manufacturer.

R

The installation shall be carried out in accordance with all applicable installation rules.

R

Panasonic assumes no responsibility for injuries or property damage resulting from
failures arising out of improper installation or operation inconsistent with this guide.
Additionally, any resulting malfunction will not be covered under the warranty.

R

After installation, make sure to leave this guide with the customer.

Summary of Contents for VL-MVN511

Page 1: ...s necessary Note to the installer R Before attempting to connect or operate this product please read the label on the rear of the doorphone and the main monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories speci...

Page 2: ...shed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not perform any actions such as fabricating twisting stretching bundling forcibly bending damaging altering exposing to heat sources or placing heavy objects on the power cable that may damage the power cable Using the product with a damaged power cable may cause electric shock short circuits or f...

Page 3: ...u will need the following additional items to install and configure the doorphone and the main monitor Locally procured Screws for mounting base 2 for mounting bracket 2 for relay box 2 3 Prepare the screws athe drawing on the right according to the material structure strength and other factors of the mounting area and the total weight of objects to be mounted 4 mm Power cables AC DC cables wires ...

Page 4: ...o water R Depending on the installation location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor R Install the main monitor away from electronic appliances such as TVs radios personal computers air conditioners boiler control panels with intercom home security equipment wireless d...

Page 5: ...P Non polarised 12 V AC DC 12 V AC DC NP NP PBX RELAY BOX A E B C D F G 1 2 D1 D2 3 4 D3 D4 5 6 R1 R2 7 8 R3 IN1 9 10 IN2 IN3 11 12 IN4 P1 13 P2 R1 1 R2 R3 S2 1 S1 S4 2 S3 2 1 You can also connect an optional lobby station for apartment complexes Connecting an optional lobby station see page 7 A Power supply 1 VL SVN511AZ models only 2 VL SVN511EX FX models only 3 VL SVN511 AZ models Use only the ...

Page 6: ... 100 m 1 Type Single pair cable with outer sheath jacket Conductor Copper solid R A certified power supply wiring has to be used with this equipment The relevant national installation and or equipment regulations shall be considered A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used 2 When using an electric lock or a co...

Page 7: ... sure to perform the following to ensure proper operation Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the lobby station Connect terminal R1 R2 on the main monitor with terminal R1 R2 on the Relay box Connect terminal S1 S2 on the Relay box with terminal S1 S2 on the lobby station After connecting to the main monitor change the Lobby connection setting to Connected devices usi...

Page 8: ...00 mm away from the camera lens When set to wide default Units mm A B G F C H E D I J A view when looking from above Image displayed on main monitor A Image range B Approx 130 C Centre of doorphone D Approx 1450 E Approx 500 F Approx 2500 G Approx 2100 H Approx 400 I Approx 170 J Approx 500 When set to zoom Displays a portion of the wide image at 2 times the size R The zoom feature uses a digital ...

Page 9: ...Approx 100 D Approx 170 Centre default Centre default C D G H F B A E A B C A Image range B Approx 80 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1900 G Approx 900 H Approx 1000 A Image range Approx 1300 B Approx 500 C Approx 105 Down Right C D G B H A E F A B C D A Image range B Approx 80 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1600 G Approx 1200 H Approx 400 A Ima...

Page 10: ...g materials 1 Attach the mounting base B accessory to the wall securely R Install the mounting base on a vertical flat wall A B C D 1 A Screws locally procured 2 VL SVN511AZ VL V555BX SX VN models included C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a hole for wiring as much as possible When using mounting box option Model No VL MB554 Install the flush mounting box A in th...

Page 11: ... 7 1 kgf cm 4 Attach the doorphone to the mounting base A Screws accessory 4 When using mounting box option Model No VL MB554 Attach the doorphone to the flush mounting box A A Screws accessory 4 5 Attach the name plate A accessory to the doorphone and use screw A B to secure the front panel R Write the name on the name plate as needed A B B Recommended torque 0 35 N m 3 6 kgf cm 11 ...

Page 12: ...able 1 Do not connect the AC cable and DC cable inversely That would be a cause of malfunctions Make sure that there are no bare wires exposed outside the product Power supply unit with cable covers removed Top view Bottom view L M J K L AC cable binder hole M DC cable binder hole 1 Strip the AC DC cables as follows AC cable A C DC cable B C 2 Remove the screws D and then remove the cable covers E...

Page 13: ...able accessory and a DC cable locally procured A B A 25 mm B7 mm Front view C D E F G H 1 1 Make sure that there are no bare wires exposed outside the product Power supply unit with cable cover removed Top view Bottom view K I J K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 Remove the screws C and then remove the cable cover D 3 Connect the AC cable E accessory to the AC I...

Page 14: ...tallation position D 80 5 mm E 86 8 mm Installing the main monitor 1 Attach the mounting bracket A to the wall securely R Install the mounting bracket on a vertical flat wall B A B C D E F G H C Screws locally procured VL SVN511AZ models included D Hole in wall E 60 mm F 83 5 mm G 7 mm H 50 mm 2 Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 ...

Page 15: ...1 2 1 2 S1 S2 S3 S4 9 button 8 6 k 7 Relay box with cable cover removed Top view Bottom view j l m L Cable binder hole 1 Strip the cables from main monitor A and cable from electric lock B C 2 Remove the screw D and then remove the cable cover E 3 Connect the cables from the electric lock F G if 2 electric locks are connected to the electric lock terminal J on the top of the relay box and then sec...

Page 16: ...1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan http www panasonic com Panasonic System Networks Co Ltd 2015 PNQP1255ZA C1015MM0 ...

Reviews: