background image

3

prevent it from falling off the wall. 
Avoid installing onto low-strength 
walls, such as gypsum board, ALC 

(autoclaved lightweight concrete), 
concrete block, or veneer (less than 
18 mm thick) walls.

Supplied accessories for installation

Important:

R

You will need the following additional items to install and configure the doorphone and the 
main monitor/extension monitor.

Note:

R

The illustrations in the supplied manual(s) may vary slightly from the actual product.

*1 VL-SV71/VL-SV72 models only
*2 VL-SV72/VL-MV72 models only

For the doorphone

*1

Screw 

×

 2

(3.8 mm 

×

 20 mm)

For the main monitor/extension monitor

Screw 

×

 2

(4 mm 

×

 16 mm)

Mounting bracket 

×

 1

Power supply unit and related items

*2

Cable binder 

×

 

1

Power supply unit 

×

 1

(VL-PS241)

AC cable 

×

 1

Screw 

×

 2

(4 mm 

×

 

40 mm)

[Locally procured]

– Power cables (AC/DC cables)

*2

 and wires (for doorphone and other connections):

Prepare wires of the appropriate specification. (

a

"Wire type and length")

prj_6905-en_gb.book  Page 3  Monday, April 24, 2017  6:10 PM

Summary of Contents for VL-MV71

Page 1: ...t please read the label on the rear of the doorphone and the main monitor extension monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories specified by the manufacturer R The installation shall be carried out in a...

Page 2: ... RDo not make any wiring connections when the power supply is turned on RDo not use the supplied power supply unit for outdoor installations it is for indoor use only RDo not install the main monitor extension monitor in the following places Places where the main monitor extension monitor may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity RD...

Page 3: ...rations in the supplied manual s may vary slightly from the actual product 1 VL SV71 VL SV72 models only 2 VL SV72 VL MV72 models only For the doorphone 1 Screw 2 3 8 mm 20 mm For the main monitor extension monitor Screw 2 4 mm 16 mm Mounting bracket 1 Power supply unit and related items 2 Cable binder 1 Power supply unit 1 VL PS241 AC cable 1 Screw 2 4 mm 40 mm Locally procured Power cables AC DC...

Page 4: ... place the doorphone in locations where echoing occurs as this will cause the doorphone to beep frequently R Make sure the rear of the doorphone is not subject to water R Depending on the installation location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor extension monitor R Lea...

Page 5: ... series Video Intercom System for Apartment Complexes is used Make sure to connect emergency terminals to the IN1 IN2 terminals Make sure to connect doorbells to the IN3 IN4 terminals A doorbell and doorphone 2 cannot be used together 3 VL SV72 VL MV72 only DOORPHONE 1 DOORPHONE 2 Electric lock Electric lock NP Non polarised MAIN MONITOR D1 D2 D3 D4 Ml 1 Ml 2 MO 1 MO 2 MO 3 MO 4 MO 5 MO 6 IN1 IN2 ...

Page 6: ...e contact 30 V AC 1 A 24 V DC 1 A or lower R Connection device for option input A contact terminal IN1 IN2 IN3 IN4 Input method No voltage contact Open circuit voltage between terminals DC 7 V or less Detection definite time 0 1 second or more Short circuit between terminals 5 mA or less Resistance value make 500 Ω or less break 15 KΩ or more Wiring run Wire type 1 Diameter Length Max Doorphone Ma...

Page 7: ...monitor Operating Instructions of the Video Intercom System R Connection for VL V900 and VL V700 series Video Intercom System for Apartment Complexes Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the VL V701 Distribution Box Note R For information about connections refer to the documentation of the VL V590 or VL V900 and VL V700 series MAIN MONITOR D1 D2 D3 D4 Ml 1 Ml 2 MO 1 MO...

Page 8: ... L Approx 87 M Approx 500 1 If the camera points 15 upwards the left or right angle is less than 7 Note The measurements and angles are for reference purposes and may vary depending on the environment A C D E G H I J K A view when looking from above B F The camera angle can be adjusted using the camera angle control lever on the rear of the doorphone step 3 Installing the doorphone so that the ima...

Page 9: ...base A Open the screw cover A B Screwdriver B Loosen the mounting screw C D Water drain holes E Mounting base 2 Attach the mounting base A to the wall securely using the wood screws B accessory R Install the mounting base on a vertical flat wall R Before drilling refer to Precautions for installation for installation location C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a h...

Page 10: ...he mounting base A Unscrew the screws Push in the wire to the terminal connectors non polar then tightly fasten the screws A B Wire connecting to the main monitor B Mount the doorphone to the mounting base Fasten the screw then close the screw cover C A Recommended torque 0 5 N m 5 1 kgf cm Maximum torque 0 7 N m 7 1 kgf cm Facing forwards Facing upwards Facing right Facing upper right A B C prj_6...

Page 11: ...ble accessory and a DC cable locally procured A 25 mm B7 mm 1 Make sure that there are no bare wires exposed outside the product K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 Remove the screws C and then remove the cable cover D 3 Connect the AC cable E accessory to the AC IN connector I on the top of the power supply unit Next connect the DC cable G locally procured to th...

Page 12: ...e height as the centre of the display R For the following reasons leave at least 20 cm A of space above below and to the left and right sides of the main monitor extension monitor To prevent malfunction and sound cutting out To ensure to make sure the reset button B can be used the reset button is on the bottom of the main monitor extension monitor R After deciding where to install the main monito...

Page 13: ...e VL SV72AZ and VL MV72AZ models Connect the DC cable and wires R Connect the wires correctly according to Wiring schematic diagram 2 1 How to connect the DC cable A Remove screw A A and then remove the terminal cover B While pressing on the button B with a pointed object such as a screwdriver insert the wires of the DC cable into the terminal connectors non polar C Make sure to replace the termin...

Page 14: ...tor 3 2 Line up the tab on the top of the bracket with the groove on the main monitor extension monitor and push the main monitor extension monitor down until it is secure Notes about electrical wiring for VL SV72 VL MV72 models Make sure not to pinch the wires as shown to the right on the mounting bracket when installing R Do not forcibly attach to the mounting bracket prj_6905 en_gb book Page 14...

Page 15: ... Panasonic Corporation 2017 PNQX8541ZA C0517MM0 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com prj_6905 en_gb book Page 16 Monday April 24 2017 6 10 PM ...