12 White Balance Adjustment
12.1. White balance adjustment
Name of measuring instrument
Connection
Remarks
·
W/B pattern
·
Color analyzer
(Minolta CA-100 or equivalent)
Component input
Panel surface
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Output a white balance pattern.
2.
Check that the color temperature is “Cool”.
3.
Set to serviceman mode, WB-ADJ.
4. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
5.
Attach the sensor of color analyzer to he center of highlight window.
6.
Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature High” in table 2.
7.
Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
8. Set color temperature to “Normal”.
9.
Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
10. Attach the sensor of color analyzer to the center of highlight window.
11. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Mid” in table 2.
12. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
13. Set color temperature to “Warm”.
14. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
15. Attach the sensor of color analyzer to the center of highlight window.
16. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Low” in table 2.
17. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
18. Set color temperature to “Cool”.
[ adjustment of “Normal” “Warm” by data shift from “Cool” adjust. ]
For “Normal” “Warm” adjustment, set values that the adjusted value of “Cool”
plus the figures wrote below.
19. Copy values adjusted by HD pattern to the NTSC data area of EEPROM.
36
TH-42PZ77U
Summary of Contents for Viera TH-42PZ77U
Page 4: ...1 Applicable signals 4 TH 42PZ77U ...
Page 19: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 19 TH 42PZ77U ...
Page 20: ...8 2 Lead of Wiring 2 20 TH 42PZ77U ...
Page 21: ...8 3 Lead of Wiring 3 21 TH 42PZ77U ...
Page 22: ...8 4 Lead of Wiring 4 22 TH 42PZ77U ...
Page 23: ...8 5 Lead of Wiring 5 23 TH 42PZ77U ...
Page 24: ...8 6 Lead of Wiring 6 24 TH 42PZ77U ...
Page 28: ...9 4 No Picture 28 TH 42PZ77U ...
Page 35: ...11 4 Adjustment Volume Location 11 5 Test Point Location 35 TH 42PZ77U ...
Page 37: ...37 TH 42PZ77U ...
Page 65: ...15 1 Schematic Diagram Note 15 Schematic and Block Diagram TH 42PZ77U 65 ...
Page 134: ...TH 42PZ77U 134 ...
Page 135: ...16 Exploded Views Replacement Parts List 16 1 Exploded Views 135 TH 42PZ77U ...
Page 136: ...16 2 Packing Exploded Views Accessories 136 TH 42PZ77U ...
Page 137: ...16 3 Packing Explode Views Stand 137 TH 42PZ77U ...
Page 138: ...16 4 Replacement Parts List Notes 138 TH 42PZ77U ...