5. Remove the screws (×2
).
6. Disconnect the connector (S2) and Remove the S-Board.
7. Remove the screws (×2
).
8. Disconnect the connectors (K1 and K2) and remove the K-
Board.
6.24. Replace the plasma panel
(finished)
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1, C2, C3-Board and the C4-Board, connect
the flexible cables (×30) from the Plasma panel to the C1,
C2, C3-Board and the C4-Board, and fit the flexible cable
holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
* When fitting the cabinet assy, be careful not to allow
any debris, dust or handling residue to remain between
the front glass and plasma panel.
17
TH-42PZ77U
Summary of Contents for Viera TH-42PZ77U
Page 4: ...1 Applicable signals 4 TH 42PZ77U ...
Page 19: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 19 TH 42PZ77U ...
Page 20: ...8 2 Lead of Wiring 2 20 TH 42PZ77U ...
Page 21: ...8 3 Lead of Wiring 3 21 TH 42PZ77U ...
Page 22: ...8 4 Lead of Wiring 4 22 TH 42PZ77U ...
Page 23: ...8 5 Lead of Wiring 5 23 TH 42PZ77U ...
Page 24: ...8 6 Lead of Wiring 6 24 TH 42PZ77U ...
Page 28: ...9 4 No Picture 28 TH 42PZ77U ...
Page 35: ...11 4 Adjustment Volume Location 11 5 Test Point Location 35 TH 42PZ77U ...
Page 37: ...37 TH 42PZ77U ...
Page 65: ...15 1 Schematic Diagram Note 15 Schematic and Block Diagram TH 42PZ77U 65 ...
Page 134: ...TH 42PZ77U 134 ...
Page 135: ...16 Exploded Views Replacement Parts List 16 1 Exploded Views 135 TH 42PZ77U ...
Page 136: ...16 2 Packing Exploded Views Accessories 136 TH 42PZ77U ...
Page 137: ...16 3 Packing Explode Views Stand 137 TH 42PZ77U ...
Page 138: ...16 4 Replacement Parts List Notes 138 TH 42PZ77U ...