background image

-  -

!

!

SAFETY PRECAUTIONS

IMPORTANT SAFEGUARDS

1. 

Read Instructions - 

All the safety and operating  instructions 

should be read before the unit is operated.

2. 

Retain  Instructions  -

  The  safety  and  operating    instructions 

should be retained for future reference.

3. 

Heed Warnings -

 All warnings on the unit and in the operating 

instructions should be adhered to.

4. 

Follow Instructions - 

All operating and user instructions  should 

be followed.

5. 

Electrical Connections - Only a qualified electrician should make 

electrical connections.

6. 

Attachments - Do not use attachments not recommended by the 

product manufacturer as they may cause hazards.

7. 

Cable  Runs  -  All  cable  runs  must  be  within  permissible 

distance.  

8. 

Mounting - This unit must be properly and securely mounted to

    a supporting structure capable of sustaining the weight of the
    unit.  Accordingly:

 

a. The installation should be made by a qualified service person, 
and should conform to all local codes.

 

b. Care should be exercised to select suitable hardware to 

install  the  unit,  taking  into  account  both  the  composition  of 
the mounting surface and the weight of the  unit. Be sure to 
periodically examine the unit and the supporting structure to 
make sure that the integrity of the installation is intact.  Failure 
to comply with the foregoing could result in the unit separating 
from the support structure and falling, with resultant damages 
or injury to anyone or anything struck by the falling unit.

UNPACKING

  Unpack carefully.  Electronic components can be damaged 

if improperly handled or dropped.  If an item appears to have 
been damaged in shipment, replace it properly in its carton 
and notify the shipper.

  Be sure to save:
1. The shipping carton and packaging material.  They are the 

safest  material  in  which  to  make  future  shipments  of  the 
equipment.

2. These Installation and Operating Instructions.

SERVICE

   For service on Panasonic/Videolarm equipment contact:
    Panasonic Technical Center
     54 West Gude Dr.
    Rockville  MD   20850-1150

    Phone:  301-762-5125
    Fax:  301-251-0347

1-800-58-6747

9:00 AM - 5:00 PM EASTERN TIME

CAUTION:  TO REDUCE THE RISK OF 

ELECTRICAL SHOCK, DO NOT EXPOSE  

COMPONENTS TO WATER OR MOISTURE.

The lightning flash with an arrowhead symbol, 

within  an  equilateral  triangle,  is  intended 
to  alert  the  user  to  the  presence  of  non-
insulated  "dangerous  voltage"  within  the 

product's enclosure that may be of sufficient 

magnitude to constitute a risk of electric shock 
to persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to presence 
of  important  operating  and  maintenance 
(servicing)  instructions  in  the  literature 
accompanying the appliance.

PANASONIC TECHNICAL SUPPORT

CAUTION

RISk OF 

ElECTRIC SHOCk!

Summary of Contents for Videolarm POD9CW

Page 1: ...for Before attempting to connect or operate this product please read these instructions completely Installation Instructions Outdoor Domed Housings POD9C W POD9CF W Manufactured By 81 IN3079 6 8 05 ...

Page 2: ... intact Failure to comply with the foregoing could result in the unit separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit UNPACKING Unpackcarefully Electroniccomponentscanbedamaged ifimproperlyhandledordropped Ifanitemappearstohave been damaged in shipment replace it properly in its carton and notify the shipper Be sur...

Page 3: ... mount bracket and close the access door Secure with the screw removed earlier 6 Clean the outside of the dome Figure 1 Access panel 3 Open the access door on the bottom of the wall mount by loosening the screw nearest the mounting plate Figure 1 1 A wall mount bracket comes standard with this unit and a template is included to use as a guide for mounting the bracket to a wall Choose the desired l...

Page 4: ...et approximately 0 1 inch 3 mm and separate the individual conductors Prepare the individual conductors for clamping If clamping use Molex brand tool part number 57027 5000 for UL listed style cable UL1015 or 57026 5000 for UL listed style cable UL1007 After clamping the contacts push them into the proper holes in the connector housing until they snap in place CAUTIONS Shrinking the cable entry se...

Page 5: ...his be done before installing the housing Figure 1 INSTALLATION FOR WV CS954 UNITIZED CAMERA 1 Connect the quick release bracket to the spacers using the 4 8 x 32 x 1 2 bolts and 8 star washers to the top of the spacers as shown Figure 1a 2 Attach the unitized camera to the quick release bracket Secure the safety screw Figure 2 Connect the BNC power control and alarm cables Make sure all wiring is...

Page 6: ...ing the 1 4 20 hex bolt provided Make final adjustments and lock down the pan tilt and height adjustment screws Figure 7 Figure 4 Figure 5 Figure 7 Tilt adjustment screw 1 4 20 hex bolt NOTE A 90 BNC connector is included in the packet to assist in fitting the camera Figure 6 Figure 6 IMPORTANT NOTE Put the dome in place to assure the camera does not touch it To reattach the dome you must twist it...

Page 7: ... RPRH708 7 Connection PCB Connection PCB Fixed Models RPFD050 Model POD9CW RPRH706 Model POD9CFW 8 Housing Hardware RPFD040 9 Housing Top RPPOD08 10 Panasonic Wall Mount PWM10 11 Captive Hardware 3 Pcs RPPOD09 Pendant Coupling Assembly Wall Mount Assembly EXPLODED VIEWS OF HOUSING Fixed Bracket Assembly 12 Quick Release Pipe Coupling SD0170 13 Pendent Housing Coupling RPPOD10 14 Pendent Mount Brac...

Page 8: ... 2 000 3 250 R 733 2 132 2 981 1 537 5 500 Mounting Template ...