Troubleshooting

Symptom

Cause / Action

Indoor unit

Noise

Sound like streaming water is heard 

during operation or after operation.

• Sound of refrigerant liquid flowing inside unit

• Sound of drainage water through drain pipe

Cracking noise is heard during operation 

or when operation stops.

Sound due to temperature changes of parts

Discharged air smells during operation.

• Indoor odor components, cigarette odor and cosmetic odor 

accumulated in the air conditioner and its air is discharged.

• The unit inside is dirty. 

(Contact your dealer.)

Dewdrops accumulate near the air outlet 

during cooling operation.

• Internal moisture is cooled by cool wind and accumulates as 

dewdrops.

Fog occurs during cooling operation.

• If the air conditioner has been installed at places such as 

restaurants where large amounts of oil mist exist, cleaning is 

necessary because the unit inside (heat exchanger) is dirty. 

(Contact your dealer.)

Fog occurs during heating operation.

• Defrost operation is in process.

The fan is rotating for a while even though 

operation stops.

• Fan rotation makes operation smooth.

• The fan may rotate to dry the heat exchanger depending on 

the setting.

Dust is discharged.

• Dust accumulated inside the indoor unit is discharged.

Outdoor unit

No operation

(When the power is turned on immediately /  

When operation is stopped and resumed 

immediately)

• Operation is not activated for the first approx. 3 minutes 

because the compressor protection circuit is activated.

Noise occurs during heating operation.

• Defrost operation is in process.

Steam comes out during heating operation.

The fan continues to rotate even after the 

operation is stopped using the remote 

controller.

• This is for smooth operation.

Check before consulting or requesting services.

01_281298_EU_En.indb   7

2016-7-1   14:40:38

Summary of Contents for U-180PE2R8A

Page 1: ...it read these operating instructions thoroughly and keep them for future reference Model No INDOOR UNIT High Static Pressure Ducted Type E2 S 180PE2R5B S 200PE2R5B S 224PE2R5B OUTDOOR UNIT Single Split Type PE2 U 180PE2R8A U 200PE2R8A U 224PE2R8A High Static Pressure Ducted Type E2 CV6233332949 01_281298_EU_En indb 1 2016 7 1 14 40 33 ...

Page 2: ... power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning In case of malfunction of this appliance do not repair by yourself Contact to the sales dealer or service dealer for a repair Thank you for purchasing this Panasonic product This produc...

Page 3: ...s To prevent possible hazards from insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips freque...

Page 4: ...witch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under the following temperature range Indoor temperature range Cooling mode 18 C 32 C DBT Heating mode 16 C 30 C DBT Outdoor temperature range Cooling mode 15 C 46 C DBT Heating mode 20 C 24 C DBT DBT Dry bulb temperature Info...

Page 5: ... the outdoor unit repeats the cycle of turning on and off automatically z z When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again z z When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically z z DRY operation is not possible if the outdoor temperature is 15 ...

Page 6: ...ed Contact your dealer Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower the temperature setting If your air conditioner does not work properly even after checking each item of Before Requesting Services and Troubleshooting z z Stop the operation immediately and turn the power off Then contact your deale...

Page 7: ...large amounts of oil mist exist cleaning is necessary because the unit inside heat exchanger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside t...

Page 8: ... 200 76 400 Heating capacity kW 20 0 22 4 25 0 BTU h 68 200 76 400 85 300 Sound Pressure level High dB A 43 47 47 Medium dB A 41 45 45 Low dB A 38 42 42 Sound Power level High dB A 75 79 79 Medium dB A 73 77 77 Low dB A 70 74 74 Unit Dimensions H W D mm 479 1 453 1 205 479 1 453 1 205 479 1 453 1 205 Net weight kg 100 104 104 Indoor unit 01_281298_EU_En indb 8 2016 7 1 14 40 38 ...

Page 9: ...ame U 180PE2R8A U 200PE2R8A U 224PE2R8A Power source 400 415 V 3N 50 Hz Cooling capacity kW 18 0 20 0 22 4 BTU h 61 400 68 200 76 400 Heating capacity kW 20 0 22 4 25 0 BTU h 68 200 76 400 85 300 Sound pressure level C H dB A 59 61 60 62 60 62 Sound power level C H dB A 77 79 79 81 79 81 Unit dimensions H W D mm 1500 980 370 1500 980 370 1500 980 370 Net weight kg 127 138 138 01_281298_EU_En indb ...

Page 10: ...10 MEMO 01_281298_EU_En indb 10 2016 7 1 14 40 39 ...

Page 11: ...11 MEMO 01_281298_EU_En indb 11 2016 7 1 14 40 39 ...

Page 12: ...Panasonic Corporation Website http www panasonic com Printed in China Panasonic Corporation 2016 85464609359020 DC0716 0 01_281298_EU_En indb 12 2016 7 1 14 40 39 ...

Reviews: