8.2.
Adjustment
8.2.1.
White balance adjustment
Name of measuring instrument
Connection
Remarks
• W/B pattern
• Color analyzer
(Minolta CA-100 or equivalent)
Component input
Panel surface
Procedure
Remarks
• Make sure the front panel to be used on the final set is fitted.
• Make sure a color signal is not being shown before adjustment.
• Put the color analyzer where there is little color variation.
1. Output a white balance pattern.
2. Check that the color temperature is [Cool].
3. Set to serviceman mode, WB-ADJ.
4. Set [R-CUT] [G-CUT] [B-CUT] the values written in table 1.
5. Attach the sensor of color analyzer to the center of highlight window.
6. Fix G drive at C0h and adjust [B-DRV] and [R-DRV] so x, y value of color analyzer
become the [Color temperature High] in table 2.
7. Increase RGB together so the maximum drive value in RGB becomes FC. That is,
set [ALL DRIVE] to FC.
Execute adjustment again. When that, the maximum value of R/G/B DRV should be FC,
and either R/G/B DRV should be FC.
8. Set color temperature to [Normal].
9. Set [R-CUT] [G-CUT] [B-CUT] the values written in table 1.
10. Attach the sensor of color analyzer to the center of highlight window.
11. Fix G drive at C0h and adjust [B-DRV] and [R-DRV] so x, y value of color analyzer
become the [Color temperature Mid] in table 2.
12. Increase RGB together so the maximum drive value in RGB becomes FC. That is,
set [ALL DRIVE] to FC.
Execute adjustment again. When that, the maximum value of R/G/B DRV should be FC,
and either R/G/B DRV should be FC.
13. Set color temperature to [Warm].
14. Set [R-CUT] [G-CUT] [B-CUT] the values written in table 1.
15. Attach the sensor of color analyzer to the center of highlight window.
16. Fix G drive at C0h and adjust [B-DRV] and [R-DRV] so x, y value of color analyzer
become the [Color temperature Low] in table 2.
17. Increase RGB together so the maximum drive value in RGB becomes FC. That is,
set [ALL DRIVE] to FC.
Execute adjustment again. When that, the maximum value of R/G/B DRV should be FC,
and either R/G/B DRV should be FC.
18. Set color temperature to [Cool].
- adjustment of [Normal] [Warm] by data shift from [Cool] adjust. -
For [Normal] [Warm] adjustment, set values that the adjusted value of [Cool]
plus the figures wrote below.
When the measurement data is not in the following tolerance by the shipping
confirmation, please re-adjust.
Tolerance : ( x , y ) = ( setting data ± 0.007, setting data ± 0.007)
19. Copy values adjusted by HD pattern to the NTSC data area of EEPROM.
Summary of Contents for TH46PZ850UA - 46" PLASMA TV
Page 16: ...16 6 4 No Picture ...
Page 29: ...29 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location ...
Page 31: ...31 ...
Page 32: ...32 ...
Page 40: ...40 10 3 Wiring 2 ...
Page 41: ...41 10 4 Wiring 3 ...
Page 42: ...42 10 5 Wiring 4 10 6 Wiring 5 ...
Page 43: ...43 11 Schematic Diagram 11 1 Schematic Diagram Note ...
Page 108: ...108 ...
Page 110: ...110 13 1 2 Fan part location ...
Page 111: ...111 13 1 3 Accessories ...
Page 112: ...112 13 1 4 Mechanical Replacement Parts List ...
Page 116: ...116 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...