2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
W
and 5.2M
W
.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
W
, 10 watts resistor, in parallel with a 0.15µF
capacitors, between each exposed metallic part on the set
and a good earth ground such as a water pipe, as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current
must
not
exceed
1/2
milliamp.
In
case
a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
1 Applicable signals
2 Safety Precautions
2.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
6
TH-37PX50U / TH-42PX50U / TH-50PX50U
Summary of Contents for TH37PX50U - 37" HD PLASMA TV
Page 24: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 TH 37PX50U 24 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 25: ...7 2 Lead of Wiring 2 TH 37PX50U 25 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 26: ...7 3 Lead of Wiring 3 TH 42PX50U 26 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 27: ...7 4 Lead of Wiring 4 TH 42PX50U 27 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 28: ...7 5 Lead of Wiring 5 TH 50PX50U 28 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 29: ...7 6 Lead of Wiring 6 TH 50PX50U 29 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 30: ...7 7 Lead of Wiring 7 30 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 31: ...7 8 Lead of Wiring 8 TH 37PX50U 31 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 32: ...7 9 Lead of Wiring 9 TH 42PX50U 32 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 33: ...7 10 Lead of Wiring 10 TH 50PX50U 33 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 37: ...8 4 No Picture 37 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 40: ...9 4 Option 40 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 44: ...10 4 Adjustment Volume Location 44 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 45: ...10 5 Test Point Location 45 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 108: ...TH 37PX50U TH 42PX50U TH 50PX50U 108...
Page 228: ...14 2 Pcaking Exploded Views 1 228 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 229: ...14 3 Pcaking Exploded Views 2 229 TH 37PX50U TH 42PX50U TH 50PX50U...
Page 230: ...14 4 Pcaking Exploded Views 3 230 TH 37PX50U TH 42PX50U TH 50PX50U...