1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
4. When servicing, observe the original lead dress.If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.2.
Touch-Current Check
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground
such as a water pipe, as shown in Figure 1.
3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above measure.
6. The potential at any point (TOUGH CURRENT) expressed as voltage U
1
and U
2
, does not exceed the following values:
For a. c.: U
1
= 35 V (peak) and U
2
= 0.35 V (peak);
For d. c.: U
1
= 1.0 V,
Note:
The limit value of U
2
= 0.35 V (peak) for a. c. and U
1
= 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0
mA d. c.
The limit value U
1
= 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz.
7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
Figure 1
Summary of Contents for TH-65PF11EK
Page 7: ...7 TH 65PF11EK 3 2 Applicable signals ...
Page 9: ...9 TH 65PF11EK 5 Operating Instructions ...
Page 14: ...14 TH 65PF11EK 6 2 IIC mode structure following items value is sample data ...
Page 35: ...35 TH 65PF11EK 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Page 37: ...37 TH 65PF11EK ...
Page 39: ...39 TH 65PF11EK ...
Page 40: ...40 TH 65PF11EK ...
Page 50: ...TH 65PF11EK 50 ...
Page 51: ...51 TH 65PF11EK 11 Wiring Connection Diagram 11 1 Wiring 1 ...
Page 52: ...52 TH 65PF11EK 11 2 Wiring 2 ...
Page 53: ...53 TH 65PF11EK 11 3 Wiring 3 ...
Page 54: ...54 TH 65PF11EK ...
Page 55: ...TH 65PF11EK 55 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Page 185: ...Model No TH 65PF11EK Note ...
Page 186: ...Model No TH 65PF11EK Exploded View ...
Page 187: ...Model No TH 65PF11EK Cabinet part location ...
Page 188: ...Model No TH 65PF11EK Fan part location ...
Page 189: ...Model No TH 65PF11EK Flat cable ...
Page 190: ...Model No TH 65PF11EK Accessories ...
Page 191: ...Model No TH 65PF11EK Packing 1 ...
Page 192: ...Model No TH 65PF11EK Packing 2 ...