Command
Command Parameter
Control details
PON
None
Power ON
POF
None
Power OFF
AVL
***
Volume 000 - 060
AMT
0
Audio MUTE OFF
1
Audio MUTE ON
IMS
None
Input select (toggle)
HM1
HDMI1 input (HDMI1)
HM2
HDMI2 input (HDMI2)
DP1
DisplayPort IN input
(DisplayPort)
DV1
DVI-D IN input (DVI-D)
PC1
PC IN input (PC)
VD1
VIDEO input (VIDEO)
YP1
COMPONENT input
(COMPONENT)
UD1
USB input (USB)
MDC
0
Tiling Enable Off
1
Tiling Enable On
DAM
None
Picture format select (toggle)
(*1)
AUZM
Auto zoom (*1)
MOEX Movie expand 16:9 (*1)
WISC
Wide screen (*1)
UNSC
Unscaled (*1)
NM43
4:3 (*1)
VPC
BLT*** Backlight 000 ~ 100 (*1)
AAC
AOV*** Audio out (External Audio
output) volume 000 ~ 060
(*1) When sending the DAM or VPC command, ensure
that the images are normally displayed with stability
beforehand. When sending a command after switching
the input, 1200 ms or more of time interval is required
after the input switching.
Attention
●
Intervals between multiple commands should be at
least 750 ms.
●
When sending multiple commands, be sure to
receive a response from this unit before sending
the next command. When sending a command
that does not require a parameter, no colon (:) is
necessary.
●
When using the serial control, set {Eco mode} to
“Normal”, and {APM} to “Off”. ( See page 31, 33)
●
When using Video Wall Manager, turn the power
“On” of this unit beforehand. Also, set {Eco mode}
to “Normal”, and {APM} to “Off”. ( See page 31,
33)
Notes
●
If a wrong command has been sent, the command
“ER401” will be returned to the PC.
●
In the standby state (power turned off by remote
control or the Display power button)
When “Eco mode” is set to ”normal”operations other
than the ”PON” command cannot be guaranteed.
●
When “Eco mode” is set to
“low power standby”operations other than the
“PON” command cannot be guaranteed. Also, the
“PON” command does not respond.
●
Only commands to monitors with corresponding IDs
will be accepted.
The formats are shown below.
(Type1) AD94;RAD:<XXX>;
(Type2) RAD:<XXX>;
<XXX> represents monitor ID 001 to monitor ID
100, or 000.
000 is the simultaneous transmission command (ID
all command) to all the monitors.
●
When using the monitors in a serial daisy chain, set
the Monitor ID to avoid overlapping in all displays,
and use commands with ID.
●
When checking the setting values on the menu
of this unit, send a command beforehand. If the
command is sent with the menu displayed, close
the menu once and open it again to check.
●
Do not send the RS232C command and PJLink
command simultaneously. The RS232C command
cannot be received while the PJLink command is
being processed. Also, no response is returned
to the RS232C command. When using the both
RS232C command and PJLink command, use
the RS232C command with an ID appended (ID:
001 to 100). If no response is returned, resend the
command.
●
For command details, consult the dealer from which
the product was purchased.
Or, visit the support site shown below.
https://panasonic.net/cns/prodisplays/
●
Video Wall Manager
This unit supports the “Video Wall Manager”
software which adjusts multiple displays
simultaneously or separately on one computer
without the need to rearrange cables.
●
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays/download/
software/index.html
IR terminal connection
It is possible to receive signals from the remote control
by connecting the supplied external IR receiver to the IR
IN terminal.
Notes
●
An external IR receiver is supplied with this unit.
●
If the external IR receiver or the IR cable is connected
to the IR IN terminal of the Display, control is limited
to this Display.
●
The remote control signal may not be received due to
the outside light or shielding objects.
●
Since the remote control signal is an asynchronous
signal to this unit, if common operations are
performed to this unit in daisy chain, some operations
may not be accepted.
English