10.2. Initialization Pulse Adjust
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Vivid
Picture : +25
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 195+10µ Sec.
Test point
Volume
Level
T2
TPSC1 (SC)
VR6602 (SC)
195 ± 10µ Sec
10.3. P.C.B. (Printed Circuit Board) exchange
10.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
10.3.2. Quick adjustment after P.C.B. exchange
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS (SS)
Vsus ± 2V
VR251 (P)
*
SC Board
Vad
TPVAD (SC)
-105V ± 1V
VR6600 (SC)
SS Board
Ve
TPVE (SS)
Ve ± 2V
VR6000 (SS)
*
D, DG Board
White blance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
33
TH-50PX60U
Summary of Contents for TH-50PX60U
Page 17: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 17 TH 50PX60U ...
Page 18: ...7 2 Lead of Wiring 2 18 TH 50PX60U ...
Page 19: ...7 3 Lead of Wiring 3 19 TH 50PX60U ...
Page 20: ...7 4 Lead of Wiring 4 20 TH 50PX60U ...
Page 21: ...7 5 Lead of Wiring 5 21 TH 50PX60U ...
Page 22: ...7 6 Lead of Wiring 6 22 TH 50PX60U ...
Page 27: ...8 4 No Picture 27 TH 50PX60U ...
Page 34: ...10 4 Adjustment Volume Location 10 5 Test Point Location 34 TH 50PX60U ...
Page 36: ...36 TH 50PX60U ...
Page 40: ...40 TH 50PX60U ...
Page 70: ...TH 50PX60U 70 ...
Page 71: ...14 Block and Schematic Diagram 14 1 Schematic Diagram Note TH 50PX60U 71 ...
Page 139: ...15 Parts Location Mechanical Replacement Parts List 15 1 Parts Location 139 TH 50PX60U ...
Page 140: ...15 2 Packing Exploded Views 140 TH 50PX60U ...
Page 142: ...16 Electrical Replacement Parts List 16 1 Replacement Parts List Notes 142 TH 50PX60U ...