11 Adjustment
11.1. White balance adjustment
Instrument Name
Connection
Remarks
·
W/B pattern
·
Color analyzer
(Minolta CA-100 or equivalent)
Component input
Panel surface
User setting: Normal
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1. Output a white balance pattern.
2. Check that the color temperature is “cool”.
3. Set to factory mode, WB-ADJ.
4. Set “R-CUT” “G-CUT” “B-CUT” 80h.
5. Attach the sensor of color analyzer to the center of highlight window.
6. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature High” in table 1.
7. Increase RGB together so the maximum drive value in RGB becomes FCh. That is, set
“ALL DRIVE” to FCh.
8. Set color temperature to “Normal”.
9. Set “R-CUT” “G-CUT” “B-CUT” 80h.
10. Attach the sensor of color analyzer to the center of highlight window.
11. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Mid” in table 1.
12. Increase RGB together so the maximum drive value in RGB becomes FCh. That is, set
“ALL DRIVE” to FCh.
* When WB-ADJ(mid) is adjusted by data-offset, set values as follows.
R-DRV : the same as R-DRV_cool
G-DRV : “G-DRV_cool” -2hDAC
B-DRV : “B-DRV_cool” -22hDAC
13. Set color temperature to “Warm”.
14. Set “R-CUT” “G-CUT” “B-CUT” 80h.
15. Attach the sensor of color analyzer to the center of highlight window.
16. Fix G drive at E0h and adjust “B-DRV” and “R-DRV so x, y value of color analyzer
become the “Color temperature Low” in table 1.
17. Increase RGB together so the maximum drive value in RGB becomes FCh. That is, set
“ALL DRIVE” to FCh.
* When WB-ADJ(warm) is adjusted by data-offset, set values as follows.
R-DRV : the same as R-DRV_cool
G-DRV : “G-DRV_cool” -AhDAC
B-DRV : “B-DRV_cool” -62hDAC
18. Set color temperature to “Cool”.
19. Copy values adjusted by HD pattern to the NTSC data area of EEPROM.
Pic Menu: Vivid
Picture: +30
ASPECT: FULL
·
Highlight section
Signal amplitude 75%
35
TH-50PX60U
Summary of Contents for TH-50PX60U
Page 17: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 17 TH 50PX60U ...
Page 18: ...7 2 Lead of Wiring 2 18 TH 50PX60U ...
Page 19: ...7 3 Lead of Wiring 3 19 TH 50PX60U ...
Page 20: ...7 4 Lead of Wiring 4 20 TH 50PX60U ...
Page 21: ...7 5 Lead of Wiring 5 21 TH 50PX60U ...
Page 22: ...7 6 Lead of Wiring 6 22 TH 50PX60U ...
Page 27: ...8 4 No Picture 27 TH 50PX60U ...
Page 34: ...10 4 Adjustment Volume Location 10 5 Test Point Location 34 TH 50PX60U ...
Page 36: ...36 TH 50PX60U ...
Page 40: ...40 TH 50PX60U ...
Page 70: ...TH 50PX60U 70 ...
Page 71: ...14 Block and Schematic Diagram 14 1 Schematic Diagram Note TH 50PX60U 71 ...
Page 139: ...15 Parts Location Mechanical Replacement Parts List 15 1 Parts Location 139 TH 50PX60U ...
Page 140: ...15 2 Packing Exploded Views 140 TH 50PX60U ...
Page 142: ...16 Electrical Replacement Parts List 16 1 Replacement Parts List Notes 142 TH 50PX60U ...