Alarm Settings
Programming Reference
4-20
DBS-EX23-530
Revised April 2000
Alarm Transmission Options
Parameter
Yellow Alarm Send
Description
Determines whether the DBS sends a yellow alarm signal to the
CO.
Programming
Master cabinet: FF1 9# 4# 4# 1# 7# (0-1)#
Slave cabinet: FF1 9# 4# 5# 1# 7# (0-1)#
Options
0=No
1=Yes
Parameter
Red Alarm Detection
Description
The default value for this parameter is determined by network
specifications. It should
not
be changed.
If a red alarm occurs, the “CFA” LED on the ISDN card lights.
Also, if the “Red Alm Relay” parameter (page 4-25) is turned on,
the alarm relay on the ISDN MDF card closes.
Note:
For changes to this parameter to take effect, the system
must be powered down, then back up again.
Programming
Master cabinet: FF1 9# 4# 4# 2#1# (0-5)#
Slave cabinet: FF1 9# 4# 5# 2# 1# (0-5)#
Options
0-5
Values
0=4
1=6
2=8
3=10
4=12
5=14