Programming Reference
ISDN System Settings
Revised April 2000
DBS-EX23-530
4-3
ISDN System Settings
System Size
T1/ISDN
Parameter
System Configuration
Description
Identifies the system size.
Note:
For changes to this parameter to take effect, the system
must be powered down, then back up again.
Programming
FF1 9# 4# 1# 1# (0-8)#
Options
0=DBS 40
1=DBS 72
2=DBS 96
3=DBS 40 + DBS 40 (ISDN must be in the slave cabinet.)
4=DBS 72 + DBS 40 (ISDN is not supported.)
5=DBS 72 + DBS 72 (ISDN must be in the slave cabinet.)
6=DBS 96 + DBS 40
7=DBS 96 + DBS 72
8=DBS 96 + DBS 96
Parameter
T1/ISDN
Description
Configures the system for either T1 or ISDN.
Programming
FF1 2# 1# 44# (0-1)#
Options
0=T1
1=ISDN