8. SERVICE DIAGNOSTIC FUNCTION
This unit is equipped with a serf-diagnostic function.
1. Trouble finding of the "CD unit"
2. Checking for the "CD control micro tip" and its operating switchs
and the LCD.
3. Checking for the "Rhythm control micro tip" and its operating
switchs and the LCD.
- Refer to the following self-diagnostic displays for the details.
- When finishing each self-diagnostic and to return to the previous
mode, turn the unit power off.
8.1. Trouble finding display of CD unit
1. Turn the power on.
2. Select "CD" from the SOURCE SELECT section.
3. Press and hold the [ ] button for at least two seconds, and while
still pressing it, press the [
] button simultaneously andhold
them for at least two seconds.
4. A "T" will appear on the display.
If the "T" incication does not appear, redo the procedure from
Step 1.