Model
Name

Model
No.

Switch-M8eGi

PN28080i-ID

Product Specification

401-28080i-ID-SP01

Panasonic Life Solutions Networks Co., Ltd.

Date revised

Date issued

May. 26, 2020

Turns on the port LED with a orange light when a loop occurs in the corresponding 
port.
At this time, the relevant port automatically shuts down to prevent loop from occurring.
SNMP trap can be sent to notify the incident to the administrator.
During loop is occurring, or if loop has occurred within the latest 3 days, 
LOOP HISTORY LED blinks to notify this.

• Loop detection port

Enabled: Ports 1 to 8 (factory default setting)
Disabled: Port 9  (factory default setting)

• Loop detection setting

Enabled (factory default setting)
Enabled/disabled can be switched by configuring a setting using 
the console, or by pressing "LED DISPLAY CHANGE BUTTON" 
for 10 seconds or more.
The setting is kept even when the power is turned OFF.

• Loop shutoff time

60 to 86,400 sec. (Factory default setting: 60 sec.)
The set time Port LED lights up orange and the port shuts off.

• Loop history retention time

3 days
The LOOP HISTORY LED lamp flashes for three days. 
The Port LED lamp also remains lit for three days after 
the loop is eliminated.

The Loop shutoff mode has the following 2 types of modes.

• Block mode (factory default setting)

When loops are detected, the ports are blocked, and just the loop 
detection packets will be transmitted and received.

• Shutdown mode

When loops are detected, the ports are shut down, and none of 
the packets including the loop detection packets will be 
transmitted nor received. (*)
* Just the loop detection packets from 30 seconds before the set 

restoration times will automatically be transmitted and received.

6-7. Loop detection

6. Software Specifications

Syslog Client (Transfers system logs to the Syslog server.)
TFTP Client (Upgrades the software and saves/loads configuration information.)
Login RADIUS (login authentication function by the RADIUS server)

6-8. Others

Summary of Contents for Switch-M8eGi Series

Page 1: ...a loop detection history function which notifies when a loop occurs with the corresponding LED and enables a network administrator to identify the looped port after the loop is removed 6 Fanless desi...

Page 2: ...e plate label Black 04 3 1 Power supply AC100 240V 50 60Hz 0 5A with a built in power supply 3 2 Power consumption 3 3 Operating environment Temperature 0 60 Humidity 20 80 RH no condensation 3 4 Stor...

Page 3: ...EEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Factory default Disable SFP extension sl...

Page 4: ...lay for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the 100Mbps or 10 Mbps transmission rate Speed mode Display for the full...

Page 5: ...nk Off Green Light Off Port LED Left Right Port LED Left Port LED Right 5 Hardware Specifications Link is established Transmitting and receiving data No device connected Link is established at 1000Mbp...

Page 6: ...on status can be checked using the following functions 1 Function to display the CPU 2 SFP module status checking function DDM Digital Diagnostic Monitoring 6 3 Rebooting 6 2 Switching Hub Control 6 4...

Page 7: ...the power is turned OFF Loop shutoff time 60 to 86 400 sec Factory default setting 60 sec The set time Port LED lights up orange and the port shuts off Loop history retention time 3 days The LOOP HIS...

Page 8: ...n EAP MD5 TLS PEAP Authentication method Web based authentication Mac based authentication using IEEE 802 1X Web based authentication Dynamic VLAN function using IEEE 802 1X Guest VLAN using IEEE 802...

Page 9: ...mount brackets to the Switching Hub 8 8 Screw for fixing the connection bracket 8 9 Power cord CEE7 7 1 The attached power cord is dedicated for AC 100 240 V use 10 2 Accessories 8 2 2 Time setting SN...

Page 10: ...125 m Multi Mode Fiber 62 5 125 m Multi Mode Fiber Maximum transmission distance 550 m at 50 125 m 220 m at 62 5 125 m 11 1 1000BASE SX SFP Module i Model No PN54022 ID 11 2 1000BASE LX SFP Module i...

Page 11: ...orrosive and combustible gases Deviation could lead to fire electrical shock and or equipment failure 8 Do not place this Switching Hub under direct sunlight and or high temperature Deviation could le...

Page 12: ...use the optical signal to not be transmitted normally and cause misoperations and malfunctions If they are contaminated make sure to clean them off then connect them to the optical fiber ports 9 This...

Page 13: ...r use this Switching Hub in the environment in accordance with the specification High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible...

Reviews: