Page 5 of 10
Model
Name
Model
No.
Switch-M2
PN28248-SG
Product Specification
401-28248-SG-SP01
Date issued
Date revised
July 4, 2016
Panasonic Eco Solutions Networks Co., Ltd.
RFC1213-MIB(MIBⅡ)
(RFC 1213)
SNMPv2-MIB
(RFC 1907)
IP-FORWARDING-MIB
(RFC 2096) only IpCidrRouteTable
RMON-MIB
(RFC 2819) Group 1,2,3,9
BRIDGE-MIB
(RFC 1493)
P-BRIDGE-MIB
(RFC 2674)
Q-BRIDGE-MIB
(RFC 2674)
IF-MIB
(RFC 2233) Other than IfTestTable
RADIUS-AUTH-CLIENT- MIB
(RFC 2618)
POWER-ETHERNET-MIB
(RFC 3621) deelxSoppConfigTable,
Other than dotlxSuppStatusTable
IEEE8021-PAE-MIB (IEEE802.1X MIB)
IEEE8023-LAG-MIB (IEEE802.3ad MIB)
RSTP-MIB
6-5. Supported MIB
6-6. System log
Turns on the port LED with a orange light when a loop occurs in the corresponding port.
At this time, the relevant port automatically shuts down (default setting: 60 sec.) to
prevent loop from occurring.
During loop is occurring, or if loop has occurred within the latest 3 days,
LOOP HISTORY LED blinks to notify this.
• Loop detection setting
Enabled (factory default setting)
Enabled/disabled can be switched by configuring a setting using
the console.
The setting is kept even when the power is turned OFF.
• Loop detection port
Enabled: Ports 1 to 24 (factory default setting)
Disabled: Ports 25 and 26 (factory default setting)
• Loop shutoff time
60 to 86400 sec. (Factory default setting: 60 sec.)
The set time Port LED lights up orange and the port shuts off.
• Loop history retention time
3 days
The LOOP HISTORY LED lamp flashes for three days.
The Port LED lamp also remains lit for three days after
the loop is eliminated.
6-7. Loop detection
6. Software Specifications
Maximum number to be kept: 1,024
Transfers system logs to the Syslog server (IPv4)
Syslog Client (Transfers system logs to the Syslog server.)
TFTP Client (Upgrades the software and saves/loads configuration information.)
SNTP Client
Login RADIUS (login authentication function by the RADIUS server)
ZEQUO assist Plus
PoE timer applications
6-8. Others