background image

Page 10 of  10

Model
Name

Model
No.

Switch-M2

PN28248-SG

Product Specification

401-28248-SG-SP01

Date issued

Date revised

July 4, 2016

Panasonic Eco Solutions Networks Co., Ltd.

14. Basic Instructions for the Use of This Product

(1) Handle the Switching Hub carefully so that fingers or hands may not be damaged by twisted pair port, SFP extension slot, 

console port, or power cord hook block.

(2) Do not connect any other devices except for 10BASE-T/100BASE-TX/1000BASE-T devices to the twisted pair ports.

Deviation could lead to equipment failure.

(3) Do not insert any other modules except for the our optional SFP module (PN54021K/PN54023K) to the SFP extension slots.

(4) Unplug the power plug when there is a malfunction.

Deviation could lead to fire if the power is allowed to be supplied for extended periods of time.

(5) Be sure to connect the ground cable.

Otherwise this might cause electrical shocks, misoperations and malfunctions.
Connect the Switching Hub via the supplied power cord to the outlet which is connected to the ground.
If the outlet is not connected to a ground, connect the ground cable to the ground terminal screw.

(6) Use the bundled power cord (AC 100 – 240 V specifications).

Deviation could lead to electric shock, malfunction, and/or equipment failure.

(7) Unplug the power cord in case of equipment failure.

Deviation, such as keeping connected for a long time, could lead to fire.

(8) Connect this Switching Hub to ground.

Deviation could lead to electric shock, malfunction, and/or equipment failure.

(9) Connect the power cord firmly to the power port.

Deviation could lead to electric fire, shock, and/or malfunction.

(10) Unplug the power cord if the STATUS LED blinks in orange (system fault).

Deviation, such as keeping connected for a long time, could lead to fire.

(11) This Switching Hub is to be periodically serviced in order to maintain its performance.

Please choose a product administrator, and have them be sure to implement periodic maintenance. When doing maintenance, 
check the inspection chart that is posted on our website which has the requisite items listed on it.

(12) When using this Switching Hub to design systems, use it after applying appropriate measures such as setting up redundant 

configurations.
Communications failures might be generated due to causes such as malfunctions or misoperations while the Switching Hub is 
being used.

(13) When using this Switching Hub for applications which require extremely high reliability, be careful to expend all possible means 

to ensure safety and reliability.
This Switching Hub was not designed nor manufactured with the intention that it be used for applications (in use with railways, 
aviation, and medical care, etc. whereas the influence rate due to communications failures is extremely high in regard to
systems that directly affect systems and human lives) which require extremely high reliability.

(14) It is strongly recommended that a lightning arrester (SPD) be installed on the twisted pair port side and the power supply side 

of this Switching Hub.
Malfunctions might be caused due to overcurrent and overvoltage due to the effects of lightning strikes.

(15) It is recommended that this Switching Hub be replaced about five years after it has been installed.

This may vary depending upon conditions such as utilisation rates and usage environments, but performance might decrease 
due to the age-related degradation, etc. of components.

(16) Be careful in regards to environmental restrictions whereby the Switching Hub can be used.

Please isolate the business power lines and communications lines. Isolate distribution lines and other distribution lines, and 
low current power lines, optical fiber cables, metallic water conduits, and gas conduits, etc. Noise may be generated in the
communications lines which might cause communications glitches.

Summary of Contents for Switch-M24eGLPWR+ Series

Page 1: ...n Ports 1 to 16 are set at MDI X default 5 Telnet allows remote configuration changes and verifications of the Switching Hub Remotely configure the PoE settings for each port Ports 1 to 24 6 Equipped with energy efficient Ethernet EEE conforming to IEEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on ...

Page 2: ...nergy saving state automatically starts so that power consumption can be reduced on each port SFP extension slot 25 26 SFF 8472 DMI Diagnostic Monitoring Interface Select either of RJ45 or SFP for use Optional Accessories 1000BASE SX SFP Module PN54021K SG 1000BASE LX SFP Module PN54023K SG 3 Rated Environmental Conditions 5 Hardware Specifications 4 1 Form and materials colors 4 2 Mass Weight 3 9...

Page 3: ...he Switching Hub is exceeding 185 W 4 FAN LED Fan sensor Green Light System is operating normally Orange Blink Fan fault is occurring 5 TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 67 factory default 6 LOOP HISTORY LED Loop History ...

Page 4: ...l connected via TELNET and SSH 3 Configuration from a remote terminal via the Internet Management protocol SNMP v1 v2c RFC1157 RFC1901 TELNET RFC854 SSH v2 RFC4251 RFC4252 RFC4253 RFC4254 RFC4716 Data transfer protocol TFTP RFC783 Switching Hub can be controlled by the following procedures 1 Control from an asynchronous terminal connected to the console port 2 Control from a remote terminal using ...

Page 5: ...loop has occurred within the latest 3 days LOOP HISTORY LED blinks to notify this Loop detection setting Enabled factory default setting Enabled disabled can be switched by configuring a setting using the console The setting is kept even when the power is turned OFF Loop detection port Enabled Ports 1 to 24 factory default setting Disabled Ports 25 and 26 factory default setting Loop shutoff time ...

Page 6: ...nction 7 6 QoS IEEE802 1p Four levels of Priority Queue supported Scheduling Method Priority Queuing PQ Strict priority queuing Weighted Round Robin WRR Weighted round robin scheduling DSCP Mapping function 7 7 Authentication Function IEEE802 1X Port based authentication EAP Packet Forwarding function Enable disable EAP transmission can be specified for each port 7 8 PoE power supply function IEEE...

Page 7: ...ion System Security Configuration ID Password Change Forwarding Database FDB Configuration Time SNTP Configuration VLAN Configuration Link Aggregation Configuration Port Monitoring Configuration QoS Configuration Storm Control Configuration Static ARP Table LLDP Configuration 802 1X Access Control Configuration Spanning Tree Configuration Loop Detection Configuration DDM Configuration RRP Domain M...

Page 8: ...le cable Fiber cable 50 125μm Multi Mode Fiber 62 5 125μm Multi Mode Fiber Maximum transmission distance 550 m at 50 125 μm 220 m at 62 5 125 μm 11 1 1000BASE SX SFP Module Model No PN54021K SG 11 2 1000BASE LX SFP Module Model No PN54023K SG Fiber optic port connector type LC connector Duplex Standards IEEE802 3z 1000BASE LX Transmission speed 1000Mbps full duplex Compatible cable Fiber cable 10 ...

Page 9: ...ead to electrical shock and or equipment failure 7 Do not insert nor drop any foreign objects such as metal or readily combustible things into the inside through the openings Deviation could lead to fire electrical shock and or equipment failure 8 Do not store or use the Switching Hub in places where it might get splashed with liquids such as water in places with a lot of humidity in places with c...

Page 10: ... periodically serviced in order to maintain its performance Please choose a product administrator and have them be sure to implement periodic maintenance When doing maintenance check the inspection chart that is posted on our website which has the requisite items listed on it 12 When using this Switching Hub to design systems use it after applying appropriate measures such as setting up redundant ...

Reviews: