7.2 Display of automatic adjustment results
(Self-Check Function)
TOP
PREVIOUS
NEXT
<Example>
Follow the below steps when E-1 is displayed.
(Cause: Focus balance (FBC) is set beyond the limit.)
l
Check if
1. the waveform or voltage of the focus servo circuit is correct, and
2. the optical pick-up returns to the normal state by exchanging the traverse deck.
Follow the below steps when E-4 is displayed.
(Cause: Focus gain (FGC) is set beyond the limit.)
l
Check if
1. the waveform or voltage of the focus servo circuit is correct,
2. the focus coil of the optical pick-up is correct (around 8 ohms), and
3. the optical pick-up returns to the normal state by exchanging the traverse deck.
Follow the below steps when E-F is displayed.
(Cause: All adjustments (TGC, FGC, TBC, FBC) are set beyond the limit.)
l
Check if