![background image](http://html1.mh-extra.com/html/panasonic/sf4b-v2-series/sf4b-v2-series_instruction-manual_3865159031.webp)
30
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
Take care that the shape of the connectors for the bottom side and for the end
cap side on the cable for series connection (
`
) is different.
The cable for series connection (
`
) cannot be extended.
When the cable for series connection (
`
) is inserted to the main sen-
sor, take care of the following. If inserted without care, the connector pins may
bend.
1) Do not insert the connector part aslant.
2) Do not pull the cables before tightening the M2.6 screws.
3) Do not insert the connector incorrectly and tighten the M2.6 screws.
There is no difference in the cable for series connection for the emitter and the receiver.
The length of the cable for series connection differs depending on the model No.
Model No.
Cable Length (mm)
SFB-CSL01
100
SFB-CSL05
500
SFB-CSL1
1,000
SFB-CSL5
5,000
<Dismantling the cable for series connection>
1. For dismantling the cable for series connection, follow the above procedure of
<Mounting
method of cable for series connection>
in reverse.
Connector
Connector
Good
Not good
Good
Fixed with M2.6 screws
<_>#Q _
Not good
<Reference>
No gap
Good
Not good
Gap