© Panasonic Industrial Devices SUNX Co., Ltd. 2014
20
Protection Area
2-3-4 Device Placement
This is the configuration when two or more sets of emitter and receiver facing each other are placed. It is
used for the case that there is a problem in wiring or for system evaluation in case of addition of equipment.
Perform an operation test by referring to “
2-6-2 Operation Test
.”
WARNING
●
Refer to the examples of device placement given below and understand them thoroughly before installing the
devices. Improper sensor placement could cause device malfunction, which can result in death or serious injury.
● If this device is used in multiple sets, arrange them to avoid mutual interference.
If mutual interference occurs, it can result in death or serious injury.
<Example of device placement>
1) Install emitter and the receiver back to back
2) Arrange the emitter and the receiver vertically on
opposite sides.
Receiver
Emitter
Emitter
Receiver
Receiver
Emitter
Emitter
Receiver
3) Arrange the emitter and the receiver horizontally
on opposite sides.
4) Install a barrier
Receiver
Emitter
Emitter
Receiver
Receiver
Emitter
Receiver
Emitter
Barrier
<Reference>
The above figures are just examples of device placement. If there are any questions or problems,
please contact our office.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com