INSTRUCTION MANUAL

Control Unit Exclusive for Light Curtain

SF-AC

ME-SFAC No.0063-81V

Thank you very much for purchasing Panasonic products.

Please read this Instruction Manual carefully and thoroughly for the correct 

and optimum use of this product.

Kindly keep this manual in a convenient place for quick reference.

English and Japanese are original instructions.

1

OUTLINE

 

● This product is a control unit exclusive for the light curtain conforming to 

European / North American safety standards and Japanese safety stan-

dards for press machines.

 

● This device complies with the following standards / regulations.

<EU Directives>

EU Machinery Directive 2006/42/EC

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU

<European Standards>

EN 60947-5-1, EN ISO 13849-1 (Category 4, PLe)

EN ISO 13849-2

<International Standards>

IEC 60947-5-1, ISO 13849-1 (Category 4, PLe), ISO 13849-2

<Japanese Industrial Standards (JIS)>

JIS B 9705-1 (Category 4)

<Standards in US / Canada)>

ANSI/UL 508, CAN/CSA C22.2 No.14

<Regulations in US>

OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19

ANSI/RIA 15.06
Regarding EU Machinery Directive, a Notified Body, BG, has certified 

with the type examination certificate.

With regard to the standards in US / Canada, a NRTL, UL (Underwriters 

Laboratories Inc.) has certified for C-UL US Listing Mark.

<Reference>

The conformity to JIS, OSHA and ANSI for this device has been evaluated by our-

selves.

2

FUNCTIONAL DESCRIPTION

SF-AC

Receiver

Power

Test

Ui

K1

K2

5.  Test input indicator

  (Test) (Yellow)

6.  Test input polarity 

selection switch

1.  Power indicator 

  (Power) (Green)

2.  Internal circuit operation

  indicator (Ui) (Green)

3.  K1 relay operation

  indicator (K1) (Green)

4.  K2 relay operation

  indicator (K2) (Green)

No.

Designation

Description

1

Power indicator

(Power) (Green)

Lights up when power is supplied.

2

Internal circuit operation

(Ui) (Green)

Lights up when both conditions are present: unit is 

powered up and electronic fuse is at normal state.

3

K1 relay operation

(K1) (Green)

Lights up when enabling contacts are closed.

4

K2 relay operation

(K2) (Green)

5

Test input indicator

(Test) (Yellow)

Lights up when X11-X12 is opened. 

6

Test input polarity selection 

switch

Selectable PNP or NPN test input polarity.

3

INSTALLATION POSITION / DIRECTION / METHOD

 

● Use the 35mm width DIN rail to install the unit.

 

● The installation position/direction is not basically limited.

 

● Please fix this product with optional DIN rail stopper 

MS-DIN-E

 after it 

installs it in 35mm width DIN rail. 

 

● Tighten the wiring to the wiring terminal block at tightening torque of 

0.6N·m.

 

● Please install and connect ferrule (sleeve) terminal when the lead wire 

of the connected equipment is a twisted wire. Please do not connect the 

twisted wire directly with the terminal.

 

● Always install this product in a control panel having an IP54 or higher 

protective structure.

4

I/O CIRCUIT DIAGRAM

*  E: Emitter, R: Receiver

  T_IN: Used to connect the test input wire (or the emission halt input wire) of light curtain.

  A_IN: Used to connect the auxiliary output wire (or the alarm output wire) of light curtain. 

Note: Please wire between X1-X2 when using it by the manual reset as shown in the figure 

below or please wire between X1-X3 when using it by the auto reset.

WARNING

Install a RESET switch in palace where it is possible to see all over the 

dangerous zone and outside of the zone.

5

CIRCUIT EXAMPLE

 

Wiring example of input part

2-channel input type

Connection of PNP transistor output

It is possible to detect the wire disconnection 

and short-circuit (against ground) by the built-in 

monitor circuit.

When the external reset signal is connected.

•  For auto reset, the external conductor B contact 

is connected to between the X1-X3 to make up 

a back-check circuit.

When the back-check function is not used, the 

jumper is connected to between the X1-X3.

When the external reset button (it makes up a 

back-up check circuit between X1-X2.) is used, 

the relay unit is operated by the signal trailing 

operation. When the product is used for auto-

start, use the other control circuit to prevent the 

system (after emergency shutdown) from be-

ing reset automatically. (Refer to the “IEC / EN 

60204-1)

•  The test input polarity selection switch S1 (ar-

ranged on rear side of upper cover) built in the 

relay unit is changed depending on the polarity of 

test input (emission halt input).

* It has been set to 'PNP' side at time of ship-

ment.

For 

SF2-EH

 series, change the slide switch to  

“NPN” side prior to use.

 

Connection example of output part

•  1-channel output

The 1-channel output is suitable for the 

strengthened type to which a relay is used, or 

for the contactor to which chamber structure 

type contact or forced guide type contact is pro-

vided.

* The external reset button is connected in se-

ries to the back-check circuit.

•  2-channel output

The 2-channel output is suitable for the 

strengthened type to which a relay is used, or 

for the contactor to which chamber structure 

type contact or forced guide type contact is pro-

vided.

* The external reset button is connected in se-

ries to the back-check circuit.

SF-AC

CONTROL-LOGIC

L1

N

Fuse 2

Fuse 1

Test

A1

F1

Power

Ui K3

K1

K2

X1 X2X3 S1 S2

X11 X12

K4

K3

K1

L1

3

M

L2 L3

K2

A_IN 51 13 2333 41

14 2434 42

T_IN

A2

PE

52

KA

KB

KA

RESET

KB

E

0V

R

0V

+
-

24V DC

±10%

+24V

(+V)

S1

+24V

(+V)

S2

X1

X2

RESET

X2

X1

X3

RESET

X1

KA

KB

KA

KB

Power

Test

NPN

PNP

Ui

K1

K2

S1

(*)

L1

13

14

KA KB

KA

KB

KA

KB

X1

X2

N

*

L1

13

14

23

24

KA KB

KA

KB

KA

KB

X1

X2

N

*