1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
(This “Safety Precaution” is applied only in U.S.A.) (For PL Only)
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
1.2. Before Use (For GCP Only)
Be sure to disconnect the mains cord before adjusting the voltage selector.
Use a minus(-) screwdriver to set the voltage selector (on the rear panel) to the voltage setting for the area in which the unit will
be used. (If the power supply in your area is 110V or 127V, set to the “127V” position.)
Note that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries,
the correct voltage is already set.)
3
SA-AK570PL / SA-AK570GCP
Summary of Contents for SA-AK570GCP
Page 7: ...7 SA AK570PL SA AK570GCP ...
Page 10: ...6 Operation Procedures 6 1 Main Unit Key Buttons Operations 10 SA AK570PL SA AK570GCP ...
Page 11: ...6 2 Remote Control Key Buttons Operations 11 SA AK570PL SA AK570GCP ...
Page 13: ...6 4 Connecting and Playing a USB Mass Storage Class Device 13 SA AK570PL SA AK570GCP ...
Page 18: ...18 SA AK570PL SA AK570GCP ...
Page 25: ...8 3 Main Components and P C B Location 25 SA AK570PL SA AK570GCP ...
Page 55: ...55 SA AK570PL SA AK570GCP ...
Page 69: ...14 1 2 Main P C B 14 1 3 SMPS P C B 69 SA AK570PL SA AK570GCP ...
Page 71: ...14 1 8 Jupiter USB P C B 71 SA AK570PL SA AK570GCP ...
Page 72: ...72 SA AK570PL SA AK570GCP ...
Page 73: ...14 2 Waveform Chart 73 SA AK570PL SA AK570GCP ...
Page 74: ...74 SA AK570PL SA AK570GCP ...
Page 76: ...SA AK570PL SA AK570GCP 76 ...
Page 86: ...86 SA AK570PL SA AK570GCP ...
Page 116: ...116 SA AK570PL SA AK570GCP ...
Page 117: ...22 Exploded Views 22 1 Cabinet Parts Location SA AK570PL SA AK570GCP 117 ...
Page 118: ...SA AK570PL SA AK570GCP 118 ...
Page 119: ...22 2 Deck Mechanism Parts Locations RAA4407 S SA AK570PL SA AK570GCP 119 ...