13.1. Cassette Deck Section
·
Measurement Condition
−
−
−
−
Reverse-mode selector switch:
−
−
−
−
Deck Tape Select: NORMAL
−
−
−
−
Make sure head, capstan and press roller are clean.
−
−
−
−
Judgeable room temperature 20 ± 5 °C (68 ± 9°F)
·
Measuring instrument
−
−
−
−
EVM (DC Electronic voltmeter)
−
−
−
−
Digital frequency counter
·
Test Tape
−
−
−
−
Tape speed gain adjustment (3 kHz, -10 dB);
QZZCWAT
13.1.1. Tape Speed Adjustment (Deck 1/2)
1. Insert the test tape (QZZCWAT) to DECK 2 and playback
(FWD side) the middle portion of it.
2. Adjust Motor VR (DECK 2) for the output value shown
below.
Adjustment target: 2910 ~ 3090 Hz (NORMAL speed)
3. After alignment, assure that the output frequency of the
DECK 1 FWD are within ±60 Hz of the value of the output
frequency of DECK 2 FWD.
Fig. 1
13.1.2. Bias Voltage Check
1. Set the unit “AUX” position.
2. Insert the Normal blank tape (QZZCRA) into DECK 2 and
the unit to “REC” mode (use “
l
REC/STOP” key).
3. Measure and make sure that the output is within the
standard value.
Bias voltage for Deck 2
14±4mV (Normal)
Fig. 2
Fig. 3
13 Measurements and Adjustments
13.1.3. Bias Frequency Adjustment (Deck 1/2)
1. Set the unit to “AUX” position.
2. Insert the Normal blank tape (QZZCRA) into DECK 2 and set the unit to “REC” mode (
l
use “REC/STOP” key).
3. Adjust L1002 so that the output frequency is within the standard value as below.
Standard Value: 89 ~ 110 kHz
Fig. 4
13.1.3.1. Cassette Deck Section
Below is the locations of test points for Deck P.C.B.:-
43
SA-AK340P / SA-AK340PC
Summary of Contents for SA-AK340P
Page 9: ...6 Accessories Remote Control FM Indoor Antenna AC Cord AM Loop Antenna 9 SA AK340P SA AK340PC ...
Page 10: ...7 Operation Procedures 10 SA AK340P SA AK340PC ...
Page 11: ...11 SA AK340P SA AK340PC ...
Page 23: ...10 3 Main Parts Location 23 SA AK340P SA AK340PC ...
Page 34: ...34 SA AK340P SA AK340PC ...
Page 40: ...12 2 Checking and Repairing of Transformer P C B 40 SA AK340P SA AK340PC ...
Page 41: ...12 3 Checking and Repairing of Panel Deck Deck Mechanism P C B 41 SA AK340P SA AK340PC ...
Page 42: ...12 4 Checking and Repairing of Power P C B 42 SA AK340P SA AK340PC ...
Page 47: ...14 2 Power P C B and Transformer P C B 47 SA AK340P SA AK340PC ...
Page 48: ...14 3 Waveform Chart 48 SA AK340P SA AK340PC ...
Page 56: ...56 SA AK340P SA AK340PC ...
Page 58: ...SA AK340P SA AK340PC 58 ...
Page 60: ...SA AK340P SA AK340PC 60 ...
Page 66: ...SA AK340P SA AK340PC 66 ...
Page 68: ...SA AK340P SA AK340PC 68 ...
Page 72: ...SA AK340P SA AK340PC 72 ...
Page 80: ...SA AK340P SA AK340PC 80 ...
Page 84: ...84 SA AK340P SA AK340PC ...
Page 85: ...21 Exploded Views 21 1 Cabinet Parts Location SA AK340P SA AK340PC 85 ...
Page 86: ...SA AK340P SA AK340PC 86 ...
Page 87: ...SA AK340P SA AK340PC 87 ...