Options

S1DXM-A/M/S1DX COMMON OPTIONS

 Accessory (Unit: mm 

inch

)

• Mounting frame (for panel mounting type)

 Terminal socket

 Socket leaf holding clip

S1DXM-A/M/S1DX COMMON OPTIONS

ADX18002 (Titanium-gray)
ADX18006 (Gray)
ADX18007 (Black)

Panel cutout dimensions

Board thickness 1 to 3 mm
Note: Make sure the holes area stays 

as right angles.

27.1

33.5

3

30

31.5

25.1

1.067

1.319

.118

1.181

1.240

.988

+

0.2

  0

5

3

25.2

+

.008

  0

.992

+

0.2

  0

31.6

+

.008

  0

1.244

*Note

.197

.118

• Protective cover

      ADX18008

• Cap block

      ADX18011

• Cap for cap block

      ADX18004

• Socket for cap block

      ADX18003

28.2

34.6

10.5

1.110

1.362

.413

30.0

36

1.417

21.2

.835

1.181

29.4

18.85

21.2

7.65

2

.079

1.157

.742

.835

.301

• HC2 slim DIN 
terminal socket

HC2-SFD-S

• HC2 DIN high 
terminal socket

HC2-SFD-K

• HC4 DIN high 
terminal socket

HC4-SFD-K

• HC4 socket

HC4-SS-K

• HJ2 terminal 
socket

HJ2-SFD/HJ2-SFD-S

• HJ4 terminal 
socket

HJ4-SFD/HJ4-SFD-S

3.248

82.5

86.5

3.406

3.248

82.5

86.5

3.406

3.248

82.5

86.5

3.406

10

.394

58.1

2.287

86.0

3.386

88.0

3.465

86.0

3.386

88.0

3.465

Notes: The triangles indicate that removal will be slightly difficult when installed laterally in 

succession.
*1. The socket line holding clip ADX18005 is enclosed in the S1DX timer.

: Available, –: Not available

*2. The socket line holding clip (ADX28005) is not included with the S1DXM-A/M 

timer.

*3. For use where there is a lot of vibration and shock, please use a compliant 

socket leaf holding clip or socket line holding clip.

Type

Application

Terminal 
socket

ADX18001

ADX18012

AD68002

ADX28005

ADX18005

For 
HC 
relay

HC2-SFD-S*

3

HC2-SFD-K*

3

HC4-SFD-K*

3

HC2-SF-K

HC4-HSF-K

HC2-SS-K

HC4-SS-K

For 
HJ 
relay

HJ2-SFD*

3

HJ2-SFD-S*

3

HJ4-SFD*

3

HJ4-SFD-S*

3

*

2

*

1

(2 pieces per set)

63.8

2.512

4.5

.177

ADX18001

ADX18012

Dimensions

Appearance

Dimensions

Appearance

(2 pieces per set)

(2 pieces per set)

63.1

2.484

4.5

.177

61.6

2.425

4.5

.177

AD68002

Dimensions

Appearance

ADX28005

52.6

2.071

7.5

.295

 Socket line holding clip 

for S1DXM-A/M 
(Sold separately)

All Rights Reserved © C

OPYRIGHT

 Panasonic Electric Works Co., Ltd.

Summary of Contents for S1DXM-M

Page 1: ...s to 60 min S1DXM A2C60M AC24V S1DXM A4C60M AC24V 0 05 min to 10 hr S1DXM A2C10H AC24V S1DXM A4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM A2C10M AC120V S1DXM A4C10M AC120V 0 2 s to 30 min S1DXM A2C30M AC120V S1DXM A4C30M AC120V 0 5 s to 60 min S1DXM A2C60M AC120V S1DXM A4C60M AC120V 0 05 min to 10 hr S1DXM A2C10H AC120V S1DXM A4C10H AC120V 200 to 220V AC 0 05 s to 10 min S1DXM A2C10M AC220V ...

Page 2: ...r S1DXM M2C10H DC24V S1DXM M4C10H DC24V 24V AC Note 0 05 s to 10 min S1DXM M2C10M AC24V S1DXM M4C10M AC24V 0 2 s to 30 min S1DXM M2C30M AC24V S1DXM M4C30M AC24V 0 5 s to 60 min S1DXM M2C60M AC24V S1DXM M4C60M AC24V 0 05 min to 10 hr S1DXM M2C10H AC24V S1DXM M4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM M2C10M AC120V S1DXM M4C10M AC120V 0 2 s to 30 min S1DXM M2C30M AC120V S1DXM M4C30M AC120V 0...

Page 3: ...nt Timed out 2 Form C Timed out 4 Form C Contact resistance Initial value Max 100mΩ at 1A 6V DC Contact material Timed out 2 Form C type Silver alloy Au plating Timed out 4 Form C type Silver alloy Au plating Life Mechanical constant Min 107 Electrical constant 2 105 at rated control capacity Mechanical Vibration resistance Functional 10 to 55Hz 1 cycle min single amplitude of 0 25mm 10min on 3 ax...

Page 4: ... UP operation LED ON power LED orange OFF green ON OFF ON Power ON delay operation MODE switch 1 OFF switch 2 OFF When power is turned on the output contact operates after the set time The output contact remains on until the power is turned off Power Flicker OFF start operation MODE switch 1 OFF switch 2 ON When the power is turned on the output contacts repeatedly operate at the set time The outp...

Page 5: ...iring diagram Timed out 2 Form C type Timed out 4 Form C type For the DC operating type terminal 14 is and terminal 13 is ON UP s m RANGE X1 X10 0 S1DXM Time range switch ON Power LED green Nameplate For 4 Form C type 28 5 1 122 16 6 654 Control time scale UP Operation LED orange 22 1 870 6 4 252 57 9 2 280 52 7 2 075 1 5 9 13 4 8 12 14 Operating voltage 13 35 526 1 5 9 2 6 10 3 7 11 13 4 8 12 14 ...

Page 6: ...3 248 82 5 86 5 3 406 3 248 82 5 86 5 3 406 10 394 58 1 2 287 86 0 3 386 88 0 3 465 86 0 3 386 88 0 3 465 Notes The triangles indicate that removal will be slightly difficult when installed laterally in succession 1 The socket line holding clip ADX18005 is enclosed in the S1DX timer Available Not available 2 The socket line holding clip ADX28005 is not included with the S1DXM A M timer 3 For use w...

Page 7: ...D K Available Not available 30 6 236 0 6 1 181 024 4 1 0 2 161 008 6 4 0 2 252 008 6 3 0 2 248 008 2 0 15 079 006 13 35 0 2 526 008 26 0 6 1 024 024 0 3 4 2 012 165 67 1 2 638 039 Terminal screw M3 21 0 6 827 024 4 1 14 12 8 13 9 5 4 157 26 30 26 1 024 1 024 30 1 181 1 181 33 5 1 319 67 2 638 10 394 Screw hole 2 M3 5 or 4 2 0 1 hole φ or 165 004 hole φ DIN high terminal socket HC4 HC4 SFD K Availa...

Page 8: ... holes 59 1 2 323 039 72 1 2 835 039 30 1 181 16 5 650 3 4 0 3 134 012 35 4 1 394 4 157 6 0 3 236 012 22 866 4 1 8 5 9 12 13 14 HJ4 terminal socket HJ4 SFD Available Available 8 7 3 9 1 5 6 2 11 12 14 4 10 13 Lot No 30 1 181 16 5 650 3 4 0 3 134 012 35 4 0 5 1 394 020 6 0 3 236 012 M3 118 terminal screw 2 M4 2 5 165 5 mounting holes 59 1 2 323 039 72 1 2 835 039 29 1 142 1 2 3 7 6 5 8 12 11 10 9 1...

Page 9: ...2 14 11 1 2 4 3 7 06 278 4 06 160 16 55 652 6 35 250 6 35 250 2 3 091 25 2 992 7 65 301 25 5 1 004 1 27 050 175 175 4 45 175 4 45 4 45 parallel installed 25 8 1 016 21 6 850 5 9 232 The interval size between the sockets which are The difference between the HC2 and HC4 sockets is only the number of the pins Their appearances and sizes are the same General tolerance 0 5 Dimensional tolerance of mach...

Page 10: ...lding clip to secure terminal sockets and sockets to the timer unit The conditions of use for dedicated socket leaf holding clip will differ depending on the terminal socket or socket you will be using Therefore please test under actual conditions before putting into operation 3 If terminals are to be soldered directly please hand solder with a 30 to 60 W solder iron with a tip temperature of 300 ...

Page 11: ... example when performing contact protection if set up like that of fig A leaking current will pass through C and R enter the timer and cause incorrect operation The fig B shows the correct setup When a contact switch having an operation indicating lamp lamp equipped limit switch etc is used to apply power to the timer a resistor having a value equal to or greater than the value below shall be conn...

Reviews: