TI040
1/2
33-00024EF-03
TI040
Installation and User Guide
Industrial Indoor / Outdoor Timer
• Line voltage selector switch (120, 208/240V)
• Can function as a regular switch or as a programmable timer
• Up to 7 programs (7 on settings / 7 off settings) per week
• A single-pole switch can be connected to the timer to control the
load similar to a 3-way installation. For example, the timer can be
installed outside whereas the switch can be located remotely (e.g.,
inside the house)
• Can be used in various applications (see table below)
1.
Cut power at the main electrical panel to avoid electric shock.
2.
Open the TI040 door and remove the plastic cover to access
the mounting holes and wire terminals.
3.
Install the TI040 to a vertical surface such as a wall by means
of three screws (not supplied).
WARNING: To prevent rain infiltration or any other liquid from the
top, the TI040 must be installed in the upright position as shown
above.
4.
Remove the necessary knockouts at the bottom of the housing.
5.
Install strain-relief bushings over the knockouts, pass the wires
through the bushings and secure them in place.
6.
Perform the connections as shown on the wiring diagram.
NOTE:
For a 3-way installation only, connect a regular single-pole
switch to the 3-way terminals of the timer as shown on the
wiring diagram.
7.
Select the proper input voltage by means of the voltage selec-
tor switch. (WARNING: Failure to do so can damage the prod-
uct.)
8.
Reinstall the plastic cover and apply power at the main electri-
cal panel.
At power-on, 0:00 should flash. Otherwise, press
reset
using a paper
clip. If the display is blank, verify the power supply.
NOTE
: The switch displays the time in 24-hour format by default or
following a reset.
1.
To change to 12-hour format (or vice versa), proceed as fol-
lows:
a) Press the
MODE
button to ensure the
MAN
or
AUTO
indica-
tor is displayed.
b) Press the
MIN
and
HOUR
buttons simultaneously and briefly
(
0:00
display = 24-hour,
12:00
display = 12-hour).
2.
Set the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.
3.
Set the day by using the DAY button.
4.
Press the MODE button to return to normal operation.
About your new timer
1.
Load type Maximum load
Examples
Resistive
load
30 A
•
incandescent lights
•
halogen lights
•
block heater
Inductive
load
10 A
•
fluorescent lights
•
compact fluorescent lights (CFL)
•
sodium lamps
•
electronic ballasts
•
LED
Motor
1.5 hp @ 120 VAC
2.0 hp @ 240 VAC
•
pool filter pumps
•
fans
Installation
2.
Knock-out
Power-up
3.
Setting the clock
4.
Power supply
(120/208/
240 VAC)
Single-pole switch
(for 3-way installation)
Line voltage
selector
switch
Motor
Lighting
• Briefly press the button to
turn the load On or Off.
• Press the button for 3
seconds to switch
between Automatic mode
and Manual mode.
Mode display
On/Off display
Program number
Insert a paperclip
to reset the timer.