WARNING
To reduce the risk of fire, electric shock or injury to persons, observe the following:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the
manufacturer.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire Protection Association (NFPA), and the American Society
of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) and the local code authorities.
Ducted exhaust fans must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
This model is UL listed for tub and shower enclosures.
If this product is no longer to be used, it must be removed from the ceiling to prevent it from falling.
Do not install with a method which is not approved in the instructions.
This product must be properly grounded.
Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion
which can cause a humming noise in the motor.
Do not disassemble the unit for reconstruction. It may cause fire or electric shock.
The ceiling joist must be able to withstand a static load of at least five times the weight of the product.
Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
Make sure that the electric service supply voltage is AC 120 V 60 Hz.
Do not install this ventilating fan in a location where the interior room temperature may exceed 104 °F (40 °C).
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational
Safety and Health Administration (OSHA).
CAUTION
Always disconnect the power source before working on or near the fan, motor or junction box.
GENERAL SAFETY INFORMATION (CONTINUED)
2
Install the fan at least 5 feet (1.5 m) above the floor.