Chapter 4
Settings — [PROJECTOR SETUP] menu
120 - ENGLISH
f
To set the projector based on luminance
Luminance (lm)
When [CONSTANT MODE] is set to [OFF]
When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Runtime (hour)
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Runtime (hour)
7 000
100.0
100.0
20 000
―
―
―
6 500
100.0
93.0
22 000
100.0
―
―
6 000
100.0
86.0
23 500
100.0
86.0
3 000
5 500
100.0
79.0
25 000
100.0
79.0
6 000
5 000
100.0
71.0
26 500
100.0
71.0
9 000
4 500
100.0
64.0
28 000
100.0
64.0
12 500
4 000
100.0
57.0
30 000
100.0
57.0
17 000
3 500
100.0
50.0
31 500
100.0
50.0
22 500
3 000
100.0
43.0
33 000
100.0
43.0
28 500
2 500
100.0
36.0
34 500
100.0
36.0
36 000
r
PT-RZ660/PT-RW620
f
To set the projector based on the duration of use
Duration of use
(hour)
When [CONSTANT MODE] is set to [OFF]
When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Luminance (lm)
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Luminance (lm)
20 000
100.0
100.0
6 000
100.0
53.0
3 200
24 000
100.0
83.0
5 000
100.0
48.0
2 900
27 000
100.0
70.0
4 200
100.0
45.0
2 700
31 000
100.0
53.0
3 200
100.0
40.0
2 400
35 000
100.0
33.0
2 000
100.0
37.0
2 200
40 000
―
―
―
100.0
33.0
2 000
f
To set the projector based on luminance
Luminance (lm)
When [CONSTANT MODE] is set to [OFF]
When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Runtime (hour)
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Runtime (hour)
6 000
100.0
100.0
20 000
―
―
―
5 500
100.0
92.0
22 000
100.0
―
―
5 000
100.0
83.0
24 000
100.0
83.0
4 000
4 500
100.0
75.0
26 000
100.0
75.0
7 000
4 000
100.0
67.0
28 000
100.0
67.0
11 000
3 500
100.0
58.0
29 500
100.0
58.0
16 000
3 000
100.0
50.0
31 500
100.0
50.0
22 500
2 500
100.0
42.0
33 500
100.0
42.0
30 000
2 000
100.0
33.0
35 000
100.0
33.0
39 000
Note
f
The runtime may be shorter than the estimation due to the influence of characteristics of each light source, conditions of use, installation
environment, etc.
f
The duration of use is referred to as the runtime when you use the projector successively. The duration of use is an estimated duration and
is not the warranty period.
f
If the runtime exceeds 20 000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
Setting [BRIGHTNESS CONTROL SETUP]
Set the operation of the brightness control function.
The [BRIGHTNESS CONTROL SETUP] setting is synchronized with the [PROJECTOR SETUP] menu
→
[BRIGHTNESS CONTROL]
→
[BRIGHTNESS CONTROL SETUP]. The most recent setting is reflected in both
items.
1) Press
as
to select [OPERATION SETTING].