S

P

E

C

F

I

L

E

PT-

AR100

Full  High-Definition  Home  Cinema  Projector

As  of  December 2011

SFL11M009-1

9 / 1 1

Control  commands

P O N

*

1

P O F

*

1

I I S

O M N

O E N

O B K

O C U

O C D

O C L

O C R

O S T

O F Z

F C 1

O S H

*

2

O V M

O W M

V S 1

V P M

O O T

O E C

O M M

D P A

D C M

O V L

O S M

Standby power on

Standby power off

Input signal selection

Menu

Enter

Return

Cursor up

Cursor down

Cursor left

Cursor right

Default

Freeze

The same function as “FUNCTION” button

Blank on/off

Picture mode switch

Waveform monitor activate/off

Aspect switch

Picture mode

Off timer

The same function as “ECO” button

The same function as “MEMORY LOAD” button

The same function as “PICTURE ADJUSTMENT” button

Color management menu

The same function as “VIERA Link” button

The same function as “SUB MENU” button

C P 1 ,   S V D ,   V I D ,   H D 1 ,   H D 2 ,   H D 3 ,   R G 1  

0 ,   1

0 ,   1 ,   2 ,   3 ,   4 ,   5 ,   6 ,   7 ,   8

N O R ,   D Y N ,   G M 1 ,   S P T ,   7 0 9 ,   C N 1 ,   V C N  

0 ,   1 ,   2 ,   3 ,   4 ,   5 ,   6 ,   7  

V X X

Gamma output level (Y)

Gamma output level (R)

Gamma output level (G)

Gamma output level (B)

Gamma input level

Trigger 1 output

Trigger 2 output

A G O S 0 = 0 1 0 0 0 0   –   A G O S 0 = 0 9 0 2 5 5

A G O S 1 = 0 1 0 0 0 0   –   A G O S 1 = 0 9 0 2 5 5

A G O S 2 = 0 1 0 0 0 0   –   A G O S 2 = 0 9 0 2 5 5

A G O S 3 = 0 1 0 0 0 0   –   A G O S 3 = 0 9 0 2 5 5

A G I S 0 = 0 1 0 0 0   –   A G O S 0 = 0 9 1 0 0

T R O I 0 = + 0 0 0 0 0   –   T R O I 0 = + 0 0 0 0 1

T R O I 1 = + 0 0 0 0 0   –   T R O I 1 = + 0 0 0 0 1

Command

Option Menu Command

Function

Parameter

Control  command  parameters

I I S

O F Z
O W M

V P M

O O T
Q V X : A G O S 0

        A G O S 1

        A G O S 2

        A G O S 3

        A G I S 0

        T R O I 0
        T R O I 1

3

1
1

3

1
6

6

6

6

5

6
6

C P 1   =   c o m p o n e n t ,   S V D   =   S - v i d e o ,   V I D   =   v i d e o ,
H D 1   =   H D M I 1 ,   H D 2   =   H D M I 2 ,   R G 1   =   c o m p u t e r
0   =   o f f ,   1   =   o n
0   =   o f f ,   1   =   f u l l   s c a n   ( Y ) ,   2   =   f u l l   s c a n   ( R ) ,   3   =   f u l l   s c a n   ( G ) ,  
4   =   f u l l   s c a n   ( B ) ,   5   =   s i n g l e   l i n e   s c a n   ( Y ) ,   6   =   s i n g l e   l i n e   s c a n   ( R ) ,  
7   =   s i n g l e   l i n e   s c a n   ( G ) ,   8   =   s i n g l e   l i n e   s c a n   ( B )

N O R   =   n o r m a l ,   D Y N   =   d y n a m i c ,   G M 1   =   g a m e   1 ,   S P T   =   s p o r t s ,  
7 0 9   =   R e c .   7 0 9 ,   C N 1   =   c i n e m a   1 ,   V C N   =   v i v i d   c i n e m a  
4   =   1 5 0   m i n ,   5   =   1 8 0   m i n ,   6   =   2 1 0   m i n ,   7   =   2 4 0   m i n
A G O S 0 = p 1 p 2 d 1 d 2 d 3 d 4
p 1 p 2   =   p o i n t   n u m b e r :   0 1   –   0 9 ,   d 1 d 2 d 3 d 4   =   o u t p u t :   0 0 0 0   –   0 2 5 5

A G O S 1 = p 1 p 2 d 1 d 2 d 3 d 4
p 1 p 2   =   p o i n t   n u m b e r :   0 1   –   0 9 ,   d 1 d 2 d 3 d 4   =   o u t p u t :   0 0 0 0   –   0 2 5 5

A G O S 2 = p 1 p 2 d 1 d 2 d 3 d 4
p 1 p 2   =   p o i n t   n u m b e r :   0 1   –   0 9 ,   d 1 d 2 d 3 d 4   =   o u t p u t :   0 0 0 0   –   0 2 5 5

A G O S 3 = p 1 p 2 d 1 d 2 d 3 d 4
p 1 p 2   =   p o i n t   n u m b e r :   0 1   –   0 9 ,   d 1 d 2 d 3 d 4   =   o u t p u t :   0 0 0 0   –   0 2 5 5

A G I S 0 = p 1 p 2 d 1 d 2 d 3
p 1 p 2   =   p o i n t   n u m b e r :   0 1   –   0 9 ,   d 1 d 2 d 3   =   o u t p u t :   0 0 1   –   0 9 9

T R O I 0 = + 0 0 0 0 0   =   l o w ,   T R O I 0 = + 0 0 0 0 1   =   h i g h
T R O I 1 = + 0 0 0 0 0   =   l o w ,   T R O I 1 = + 0 0 0 0 1   =   h i g h

Command

Size (Byte)

Parameter

*1 PON  is  the  only  command  that  is  effective  in  standby  mode;  all  other  commands  are  invalid.  The  PON  command  is  not  accepted  during  lamp

on  control.  After  the  lamp  has  been  turned  off  and  while  the  cooling  fan  is  still  operating,  lamp  on  control  will  not  be  activated  for  about  85
seconds  in  order  to  protect  the  lamp.

*2 Do  not  send  OSH  commands  continuously  in  a  short  period  of  time.  Doing  so  may  burst  the  lamp  or  shorten  the  lamp  replacement  cycle.

Summary of Contents for PT-AR100

Page 1: ...S P E C F I L E Product Number PT AR100 Product Name Full High Definition Home Cinema Projector As of December 2011 Specifications and appearance are subject to change without notice SFL11M009 1 1 1 1 ...

Page 2: ...fV 60 Hz 625i 576i fH 15 63 kHz fV 50 Hz 525p 480p fH 31 50 kHz fV 60 Hz 625p 576p fH 31 25 kHz fV 50 Hz 750 720 60p fH 45 00 kHz fV 60 Hz 750 720 50p fH 37 50 kHz fV 50 Hz 1125 1080 60i fH 33 75 kHz fV 60 Hz 1125 1080 50i fH 28 13 kHz fV 50 Hz 1125 1080 24p fH 27 00 kHz fV 24 Hz 1125 1080 60p fH 67 50 kHz fV 60 Hz 1125 1080 50p fH 56 25 kHz fV 50 Hz fH 15 75 kHz fV 60 Hz NTSC NTSC4 43 PAL M PAL60...

Page 3: ...ssible image Occasionally a few pixels may remain turned on bright or turned off dark Please note that this is an intrinsic characteristic of the manufacturing technology that affects all products using LCD technology 2 The projector uses a high voltage mercury lamp that contains high internal pressure This lamp may break emitting a large sound or fail to illuminate due to impact or extended use T...

Page 4: ...380 14 31 32 35 1 3 8 137 5 13 32 151 5 15 16 14 9 16 345 13 19 32 Dimensions unit mm inch NOTE This illustration is not drawn to scale Terminals 1 HDMI 1 input 2 HDMI 2 input 3 Computer input 4 Component YPBPR YCBCR input 5 S Video input 6 Video input 7 Trigger input Trigger output 1 8 Trigger input Trigger output 2 9 Serial input 1 2 3 4 5 7 8 6 9 ...

Page 5: ...0 28 m 0 37 m 0 47 m 0 56 m 0 21 m 0 27 m 0 32 m 0 37 m 0 42 m 0 48 m 0 53 m 0 64 m 0 80 m 1 06 m 1 33 m 1 59 m 40 50 60 70 80 90 100 120 150 200 250 300 3 8 4 8 5 7 6 6 7 6 8 5 9 5 11 4 14 2 19 0 23 9 28 7 7 6 9 5 11 4 13 3 15 2 17 1 19 0 22 10 28 7 38 1 47 8 57 3 3 4 4 5 6 7 7 9 11 1 3 1 7 1 10 8 11 1 1 1 3 1 5 1 7 1 9 2 1 2 7 3 6 4 4 5 3 1 11 2 4 2 10 3 3 3 9 4 3 4 9 5 7 7 1 9 5 11 9 14 1 2 3 2...

Page 6: ...dard position of projected image 3 0 3 0 1 0 1 0 Shift range Optical axis shift function allows to shift the position of a projected image as shown below Installable angle Install the projector at an angle within the range shown below Vertical direction The projector may be installed at a vertical angle of 30 Horizontal direction The projector may be installed at a horizontal angle of 10 ...

Page 7: ... 1 920 1 080 1 920 1 080 1 920 1 080 640 480 640 480 640 480 800 600 800 600 800 600 800 600 800 600 1 024 768 1 024 768 1 024 768 1 024 768 1 152 864 1 152 864 1 280 720 1 280 768 1 280 800 1 280 1 024 1 400 1 050 1 440 900 1 920 1 080 1 920 1 080 1 920 1 200 15 7 15 6 15 7 15 6 31 5 31 3 45 0 37 5 33 8 28 1 27 0 67 5 56 3 31 5 37 5 43 3 35 2 37 9 48 1 46 9 53 7 48 4 56 5 60 0 68 7 64 0 67 5 44 8...

Page 8: ...l input Description NC Transmitted data Received data NC Ground Signal name TXD RXD GND No 1 2 3 4 5 Description NC Connected internally Connected internally NC Signal name RTS CTS No 6 7 8 9 CAUTION When sending multiple commands be sure to send the next command after receiving a response from the projector STX and ETX are character codes Expressed in hexidecimals STX is 02 and ETX is 03 STX C1 C...

Page 9: ...ction Parameter Control command parameters IIS OFZ OWM VPM OOT QVX AGOS0 AGOS1 AGOS2 AGOS3 AGIS0 TROI0 TROI1 3 1 1 3 1 6 6 6 6 5 6 6 CP1 component SVD S video VID video HD1 HDMI1 HD2 HDMI2 RG1 computer 0 off 1 on 0 off 1 full scan Y 2 full scan R 3 full scan G 4 full scan B 5 single line scan Y 6 single line scan R 7 single line scan G 8 single line scan B NOR normal DYN dynamic GM1 game 1 SPT spo...

Page 10: ... 7 single line scan G 8 single line scan B QVX AGOS0 p1p2 AGOS1 p1p2 AGOS2 p1p2 AGOS3 p1p2 AGIS0 p1p2 Gamma output level Y Gamma output level R Gamma output level G Gamma output level B Gamma input level AGOS0 p1p2d1d2d3d4 p1p2 point number 01 09 d1d2d3d4 output 0000 0255 AGOS1 p1p2d1d2d3d4 p1p2 point number 01 09 d1d2d3d4 output 0000 0255 AGOS2 p1p2d1d2d3d4 p1p2 point number 01 09 d1d2d3d4 output...

Page 11: ...e and exhaust openings are not blocked Take particular care to ensure that hot air from the exhaust openings is not sucked into the intake openings 100 mm 3 15 16 or more 100 mm 3 15 16 or more 100 mm 3 15 16 or more Direction of air intake and exhaust Intake Exhaust Operating the projector continuously 1 If the projector is to be operated continuously 6 hours or more lamp replacement cycle durati...

Reviews: