14
Switch two types of Base modes and their LEDs in the following way:
When Base mode is Status mode (factory default setting)
* The Base mode is retained even after the power is turned off.
The mode LEDs correspond to the LEDs of Ports 1 to 24 as shown in Table 1. (See p. 12.)
When Base mode is ECO mode
Switch Base mode (keep pressing "LED DISPLAY
CHANGE BUTTON" over 3 seconds)
Press "LED DISPLAY CHANGE BUTTON" manually.
Automatic
Automatically returns to Base mode after 1 minute.
Boot
Status mode
(Base mode)
GIGA mode
Speed mode
DUPLEX
mode
Loop History
mode
About Loop detection
Turns on the port LED with a orange light when a loop occurs in the corresponding port. At this
time, the relevant port automatically shuts down (default setting: 60 sec.) to prevent loop from
occurring.
If the loop is still not removed, the port will shut down again. Remove the loop while the port is shut
down.
During loop is occurring, or if loop has occurred within the latest 3 days, LOOP HISTORY LED blinks
to notify this. It is possible to switch loop detection setting (OFF/ON) by using a console cable (for
detail, see the attached CD-ROM) or by pressing "LED DISPLAY CHANGE BUTTON" for 10 seconds or
more. (The default setting is ON.) When it is switched successfully, LOOP HISTORY LED lights up and
setting is complete.
If you wish to clear loop detection history, turn OFF once the power supply of the Switching Hub
and turn it ON again.
Then, loop detection history is deleted.
The Switching Hub can hold up to 64 loop history logs.
PoE mode
Press "LED DISPLAY CHANGE BUTTON" manually.
Automatic
Automatically returns to Base mode after 1 minute.
Boot
ECO mode
(Base mode)
PoE
mode
Status
mode
GIGA
mode
Speed
mode
DUPLEX
mode
Loop History
mode
Part Names and Functions