background image

Convergent Reflective Micro Photoelectric Sensor 

PM2

 

SERIES  

5

SENSING CHARACTERISTICS (TYPICAL)

Sensing fields

Horizontal (left and right) direction

The sensors can be mounted 

side by side.

However, if the sensor 

is slanted, there may be 

interference.

Verify first whether there is any 

interference prior to use.

Vertical (up and down) direction

2

0.079

1

0.039

1

0.039

2

0.079

Operating point ℓ (mm 

in

)

Setting distance 

(mm 

in

)

Center 

Right 

Left 

Distance to  convergent point

 

White 

N5 

2

0.079

5

0.197

10

0.394

8

0.315

4

0.157

6

0.236

Distance to  convergent point

 

Operating point ℓ (mm 

in

)

Setting distance 

(mm 

in

)

Center 

Down 

Up 

White 

N5 

0.079

0.157

10 

0.197

0.236

0.315

0.394

2

0.079

1

0.039

1

0.039

2

0.079

The sensors can be mounted 

side by side.

However, if the sensor 

is slanted, there may be 

interference.

Verify first whether there is any 

interference prior to use.

Vertical direction 

ℓ 

15 × 15 mm

 0.591 × 0.591 in

 

Non-glossy paper

Sensor 

Correlation between lightness and sensing range

N2 

Lightness 

Light 

Dark 

N4 

N6 

N8 

N2 

N1 

N3 N4 N5 N6  N7  N8  N9 

Sensing range 

L (mm 

in

)

 

Distance to  convergent point

 

0.079

0.157

10 

0.197

0.236

0.315

0.394

Sensing region 

The sensing region (typical) 

is represented by oblique 

lines in the left figure.

However, the sensitivity 

should be set with enough 

margin because of slight 

variation in products.

Correlation between material (15 × 15 mm 

0.591 × 0.591 in

) and sensing range

The bars in the graph 

indicate the sensing range 

(typical) for the respective 

material. However, there 

is a slight variation in the 

sensing range depending on 

the product.

Further, if there is a 

reflective object (conveyer, 

etc.) in the background of 

the sensing object, since 

it affects the sensing, 

separate it by more than 

twice the sensing range 

shown in the left graph.

Mirror 

Glossy stainless steel   Glossy copper plate 

Non-glossy aluminum plate 

White non-glossy paper  White ceramic circuit board

 

Glass epoxy printed circuit board  (Green masked surface)

 

Black-painted, non-glossy iron plate

 

Gray non-glossy paper (N5)

 

Sensing range 

(mm 

in

)

Distance to convergent point 

 

0.197

0.394

0.591

0.787

10 

15 

20 

Lightness shown on the left 

may differ slightly from the 

actual object condition.

PRECAUTIONS FOR PROPER USE

All models

When fixing the sensor with screws, use M3 screws and

the tightening torque should be 0.49 N·m or less.

Further, use small, round type plain washers (ø6 mm

ø0.236 in

).

M3 screws 

Plain washer 

(Outer dia: ø6 mm 

ø0.236 in

Spring washer 

Purchase separately.

Mounting

Others

Do not use during the initial transient time (50 ms) after the

power supply is switched on.

Take care that the product does not come in direct contact

with oil, grease, or organic solvents, such as, thinner, etc.

Wiring

Make sure to connect terminals correctly as the sensor

does not incorporate a reverse polarity protection circuit.

If the sensor is being used in a noisy environment,

examine the extent of noise. Further, if equipment, such

as motor, solenoid or electromagnetic valve, which

generates a large surge, is present near the sensor,

connect a surge absorber to the equipment.

Setting

• T

he optimum setting

distance (distance to 

convergent point) is

 

5 mm 

0.197 in

.

The sensor is not affected 

even by a specular 

background if it is located 

 

30 mm 

1.181 in

, or more, 

away from the sensor.

5 mm 

0.197 in 

Sensor 

Sensing 

object 

Background 

30 mm 

1.181 in 

or more 

However, the specular background should be a plane 

surface, directly facing the sensor. A spherical or curved 

background may be detected.

Sensor 

15 × 15 mm

 0.591 × 0.591 in

 

Non-glossy paper

ℓ 

Horizontal direction 

Never use this product as a sensing device

for personnel protection.

In case of using sensing devices for

personnel protection, use products which

meet laws and standards, such as OSHA,

ANSI or IEC etc., for personnel protection

applicable in each region or country.

Summary of Contents for PM2 Series

Page 1: ...2022 7 Amplifier Built in Convergent Reflective Micro Photoelectric Sensor PM2SERIES The contents of this catalog are as of October 2017 For the latest information please visit our company website ...

Page 2: ...ackground Sensing object However the specular background should be a plane surface directly facing the sensor A spherical or curved background may be detected Dark object detectable Since the sensor is very sensitive it can detect even a dark object of low reflectivity Optimum setting distance is 5 mm 0 197 in approx Minute object detectable A ø0 05 mm ø0 002 in copper wire can be detected at a di...

Page 3: ... PM2 LL10B Dark ON Cable type Top sensing PM2 LH10 C1 Light ON PM2 LH10B C1 Dark ON Front sensing PM2 LF10 C1 Light ON PM2 LF10B C1 Dark ON L type Top sensing PM2 LL10 C1 Light ON PM2 LL10B C1 Dark ON APPLICATIONS Sensing capacitors in a tray OPTIONS Designation Model No Description Connector CN 13 Dedicated connector Connector attached cable CN 13 C1 0 2 mm2 3 core cabtyre cable 1 m 3 281 ft long...

Page 4: ...ℓx or less at the light receiving face Vibration resistance 10 to 55 Hz frequency 1 5 mm 0 059 in double amplitude in X Y and Z directions for two hours each Shock resistance 500 m s2 acceleration 50 G approx in X Y and Z directions three times each Emitting element Infrared LED Peak emission wavelength 880 nm 0 035 mil modulated Material Enclosure Polycarbonate Terminal part Copper alloy Ag plate...

Page 5: ...s steel Glossy copper plate Non glossy aluminum plate White non glossy paper White ceramic circuit board Glass epoxy printed circuit board Green masked surface Black painted non glossy iron plate Gray non glossy paper N5 Sensing range L mm in Distance to convergent point 0 5 0 197 0 394 0 591 0 787 10 15 20 Lightness shown on the left may differ slightly from the actual object condition PRECAUTION...

Page 6: ...below figure Sensor Connector Wiring The cable length must be 2 m 6 562 ft or less with 0 3 mm2 or more cable If the cable is extended for more than 2 m 6 562 ft connect a capacitor of 10 µF approx between V and 0 V terminals 0V OUT V 10 µF Cable 5 to 24 V DC 10 Sensor PM2 LH10 PM2 LH10B 10 0 394 5 0 197 3 3 0 130 7 2 0 283 Sensing surface 26 1 024 20 0 787 14 0 551 Operation indicator Red 2 elong...

Page 7: ...ownloaded from our website 15 0 591 14 0 551 2 0 079 7 2 0 283 Operation indicator Red ø3 7 ø0 146 cable 1 m 3 281 ft long 2 elongated mounting holes Sensing surface 10 0 394 3 2 0 126 ø5 2 ø0 205 8 4 0 331 4 0 157 5 4 0 213 3 1 0 122 5 0 197 15 0 591 1 0 039 3 3 0 130 14 0 551 20 0 787 26 1 024 7 0 276 12 4 0 488 17 0 669 25 0 984 Sensing surface 7 0 276 ø5 2 ø0 205 12 4 0 488 ø3 7 ø0 146 cable 1...

Page 8: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Reviews: