INSTALLATION  

GENERAL 

Please read this guide completely before 

installation or use of the modules. 

OPERATING CONDITIONS 

Panasonic recommends that modules be 

operated  within  the  following  Operat-

ing  Conditions.  An  installation  location 

with  conditions  beyond  the  Operating 

Conditions  or  with  other  Special  Condi-

tions  (see  below)  should  be  avoided.  

Operating Conditions of Panasonic mod-

ules are as follows: 

1) The modules should be operated only 

in  terrestrial  applications.  No  space  or 

other Special Conditions. 

2)  The  operating  temperature  must  be 

within –40°C to 85°C. 

3)  The  relative  humidity  should  be  with-

in 45% to 95%. 

4) The wind pressure load of the installa-

tion  site  should  be  less  than  2,400N/m

2

 

(50PSF). 

UNPACKING AND HANDLING 

 

Do not hit the back sheet of a mod-

ule by the connector when unpack-

ing and handling. 

 

Please do not expose the connector 

the rain water and dust . 

 

To  avoid  the  damage  of  the  back 

sheet

 

by  the  connector,  fix  the 

cables to the frame with tape after 

unpacking. (refer Figure 4) 

 

Do  not  handle  modules  by  their 

cables  or  junction  box.  Handle 

them by the frame with both hands 

in any situation. 

 

The  anti-reflection  glass  of  a  mod-

ule  is  easy  to  be  soiled,  when  it  is 

grasped by hand or hand gloves. So 

it  is  recommended  to  hold  card-

board  or  frames  when  carrying  or 

installing  the  solar  module.  When 

cables  and  connectors  touch  the 

surface  of  the  glass,  it  may  soil  the 

surface too. It is also recommended 

to avoid contact of cables and con-

nectors with surface of the glass. (If 

the glass surface becomes dirty, see 

section  of  "anti-reflection  glass  sur-

face cleaning".)  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4. Fixing of cables 
and connectors

 

Summary of Contents for Photovoltaic Module HIT VBHN SJ25 Series

Page 1: ...and service names listed in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank you for choosing Panasonic photovoltaic module HITTM Please read this manual completely before you install or use of HITTM With proper operation and maintenance HITTM will provide you with clean ren...

Page 2: ...ng higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 45 V and or modules rated for maximum system voltage in excess of 45 V Wear suitable clothing gloves and guards to prevent from direct con tact with 30 VDC or greater Work only in dry conditions with dry modules and dry tool...

Page 3: ...ngs con ductor capacities fuse sizes and size of controls connected to the module output 3 The current output for the modules shown in the Specifications is meas ured at Standard Test Conditions These conditions may not be fre quently observed in actual practice Table 1 1 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Model VBHN240SJ25 VBHN...

Page 4: ...ns of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A Note Fixing span must not exceed 1040mm Figure 1 1 b Optional Mounting Range B Note Fixing span must not exceed 1040mm Enlarged view G1 G2 ...

Page 5: ...e Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Section A A Section B B Note A module is installed using 4 points symmet rical mounting within setting range shaded Front side Figure...

Page 6: ...t may cause reverse voltage across cells or mod ules because the current from oth er cells in the same series is forced to flow through the shaded area This may cause undesirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduc tion All modules are equipped with fac tory installed bypass diodes The factory installed diodes provide prop...

Page 7: ...CKING AND HANDLING Do not hit the back sheet of a mod ule by the connector when unpack ing and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet by the connector fix the cables to the frame with tape after unpacking refer Figure 4 Do not handle modules by their cables or junction box Handle them by the frame with both hands in any situation T...

Page 8: ... that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is re quired to allow cooling air to circu late around the back of the module This also allows any condensation or moisture to dissipate Install mod ules so that air can circulate be tween the roof and the module Do not contact a tip of a mounting bolt to back sheet of the module when fixing ...

Page 9: ... Rail M8 Bolt Spring washer M8 Nut Flat washer Flat washer Spring washer Solar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 2 Module Installation VBHNxxxSJ47 Installation reference ...

Page 10: ...allation manual of connection devices Do not connect modules in parallel without maximum over current pro tection ARRAY WIRING The term array is used to describe the assembly of several modules on a support structure with associated wiring When installing a PV array the sys tem design must be completed with reference to the module electrical specifications for proper selection of inverters fuses b...

Page 11: ...s to clean any part of the module The per formance of a solar module may be reduced Please be very careful since the guarantee will not cover damages caused by detergents When cleaning the PV module please do not put detergent on junction box or connector If deter gents and chemical substances ad here junction box and connector may be deteriorated or damaged DISPOSAL OF OLD EQUIPMENT This symbol o...

Page 12: ...2 886 6295 Panasonic Life Solutions Sales Thailand Co Ltd Tel 66 0 2 231 3683 Fax 66 0 2 231 3899 Panasonic Life Solutions Hong Kong Co Ltd Tel 852 2466 1708 Fax 852 2466 1473 Panasonic Eco Solutions Sales Taiwan Co Ltd Tel 886 2 2581 6020 Fax 886 2 2581 6354 Panasonic Latin America S A Tel 507 229 2955 Fax 507 229 3297 Panasonic de México S A de C V Tel 52 55 5488 1000 Fax 52 55 5488 1015 Panason...

Reviews: