MAINTENANCE 

 

In  order  to  maintain  the  optimum 

output of the module, quality and 

safety,  please  conduct  periodic 

inspection or cleaning. 

 

It  is  also  recommended  to  inspect 

the  electrical  and  mechanical  con-

nections annually. 

 

If  you  need  electrical  or  mechani-

cal inspection or maintenance, it is 

recommended  to  have  a  licensed 

authorized  professional  carry  out 

the  inspection  or  maintenance  to 

avoid the hazards of electric shock 

or injury. 

ANTI-REFLECTION  GLASS  SUR-

FACE CLEANING 

 

Light dirt that does not shield light 

completely  does  not  significantly 

degrade power generation perfor-

mance,  but  if  the  module  surface 

becomes  dirty,  it  may  reduce  out-

put power. malfunction or hotspot 

may occur. 

 

It  is  recommended  to  clean  the 

surface  of  the  module  with  water 

and a soft cloth or sponge. 

 

When  cleaning  with  neutral  glass 

detergent  or  weak  alkaline  glass 

detergent,  it  is  recommended  to 

start  with  smallest  area  and  from 

the  edge  of  solar  module  in  order 

to  check  no  damage  occurs  to  the 

glass. 

 

After  that,  clean  surface  of  glass 

with wet and clean cloth. 

 

Recommended  detergent:  "Glass 

Magiclean"1)  or  "Windex®  Origi-

nal"2) 

1)  Glass  Magiclean  is  a  trademark 

of Kao Corporation. 

2)  Windex®  is  a  trademark  of  SC 

Johnson & Son,Inc. 

 

It is recommended to read careful-

ly  the  manuals  of  detergent  and 

understand  notes  on  usage  and 

first-aid treatment. 

 

To  remove  persistent  dirt,  the 

module  can  be  washed  with  a 

micro-fiber cloth and ethanol. 

 

Never  use  abrasive  detergent, 

strong  alkaline  detergent,  strong 

acid  detergent  or  a  detergent 

which  forms  a  protective  layer  on 

the  surface  of  the  glass  to  clean 

any  part  of  the  module.  The  per-

formance  of  a  solar  module  may 

be  reduced.  Please  be  very  careful 

since  the  guarantee  will  not  cover 

damages caused by detergents. 

 

When  cleaning  the  PV  module, 

please  do  not  put  detergent  on 

junction box or connector. If deter

-gents and chemical substances ad-

here,  junction  box  and  connector 

may be deteriorated or damaged. 

 

DISPOSAL OF OLD EQUIPMENT 

This  symbol  on  the  products, 

and/or  accompanying  docu-

ments  means

 

that  used  elec-

trical  and  electronic  products 

must not be mixed with gen-

eral household waste.  

For  proper  treatment,  recovery  and 

recycling  of  old  products,  please  take 

them

 

to  applicable  collection  points  in 

accordance  with  your  national  legisla-

tion. 

For  more  information  about  collection 

and  recycling,  please  contact  your  local 

municipality. 

Penalties  may  be  applicable  for  incor-

rect  disposal  of  this  waste,  in  accord-

ance with national legislation. 

DISCLAIMER OF LIABILITY 

Panasonic  does  not  assume  responsibil-

ity  and  expressly  disclaims  liability  for 

loss, damage, or expense arising out of, 

or  in  any  way  connected  with  installa-

tion, operation, use, or maintenance by 

using this manual.   

Panasonic  assumes no  responsibility for 

any  infringement  of  patents  or  other 

rights of third parties, which may result 

from use of modules.  

No  license  is  granted  by  implication  or 

under  any  patent  or  patent  rights.  The 

information  in  this  manual  is  believed 

to  be  reliable,  but  does  not  constitute 

an  expressed  and/or  implied  guaran-

tee.  

As  part  of  our  policy  of  continuous 

improvement,  Panasonic  reserves  the 

right  to  make  changes  to  the  product, 

specifications,  or  manual  at  any  time 

without prior notice. 

The  return  of  any  modules  will  not  be 

accepted  by  Panasonic  unless  prior 

written  authorization  has  been  given 

by Panasonic. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Photovoltaic Module HIT VBHN SJ25 Series

Page 1: ...and service names listed in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank you for choosing Panasonic photovoltaic module HITTM Please read this manual completely before you install or use of HITTM With proper operation and maintenance HITTM will provide you with clean ren...

Page 2: ...ng higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 45 V and or modules rated for maximum system voltage in excess of 45 V Wear suitable clothing gloves and guards to prevent from direct con tact with 30 VDC or greater Work only in dry conditions with dry modules and dry tool...

Page 3: ...ngs con ductor capacities fuse sizes and size of controls connected to the module output 3 The current output for the modules shown in the Specifications is meas ured at Standard Test Conditions These conditions may not be fre quently observed in actual practice Table 1 1 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Model VBHN240SJ25 VBHN...

Page 4: ...ns of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A Note Fixing span must not exceed 1040mm Figure 1 1 b Optional Mounting Range B Note Fixing span must not exceed 1040mm Enlarged view G1 G2 ...

Page 5: ...e Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Section A A Section B B Note A module is installed using 4 points symmet rical mounting within setting range shaded Front side Figure...

Page 6: ...t may cause reverse voltage across cells or mod ules because the current from oth er cells in the same series is forced to flow through the shaded area This may cause undesirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduc tion All modules are equipped with fac tory installed bypass diodes The factory installed diodes provide prop...

Page 7: ...CKING AND HANDLING Do not hit the back sheet of a mod ule by the connector when unpack ing and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet by the connector fix the cables to the frame with tape after unpacking refer Figure 4 Do not handle modules by their cables or junction box Handle them by the frame with both hands in any situation T...

Page 8: ... that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is re quired to allow cooling air to circu late around the back of the module This also allows any condensation or moisture to dissipate Install mod ules so that air can circulate be tween the roof and the module Do not contact a tip of a mounting bolt to back sheet of the module when fixing ...

Page 9: ... Rail M8 Bolt Spring washer M8 Nut Flat washer Flat washer Spring washer Solar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 2 Module Installation VBHNxxxSJ47 Installation reference ...

Page 10: ...allation manual of connection devices Do not connect modules in parallel without maximum over current pro tection ARRAY WIRING The term array is used to describe the assembly of several modules on a support structure with associated wiring When installing a PV array the sys tem design must be completed with reference to the module electrical specifications for proper selection of inverters fuses b...

Page 11: ...s to clean any part of the module The per formance of a solar module may be reduced Please be very careful since the guarantee will not cover damages caused by detergents When cleaning the PV module please do not put detergent on junction box or connector If deter gents and chemical substances ad here junction box and connector may be deteriorated or damaged DISPOSAL OF OLD EQUIPMENT This symbol o...

Page 12: ...2 886 6295 Panasonic Life Solutions Sales Thailand Co Ltd Tel 66 0 2 231 3683 Fax 66 0 2 231 3899 Panasonic Life Solutions Hong Kong Co Ltd Tel 852 2466 1708 Fax 852 2466 1473 Panasonic Eco Solutions Sales Taiwan Co Ltd Tel 886 2 2581 6020 Fax 886 2 2581 6354 Panasonic Latin America S A Tel 507 229 2955 Fax 507 229 3297 Panasonic de México S A de C V Tel 52 55 5488 1000 Fax 52 55 5488 1015 Panason...

Reviews: